Service manual

3
WARNING
THROTTLE REQUIREMENTS
NOTE: S&S Super E and G carburetors require the use of a two cable, pull open - pull closed throttle assembly. All 1980 and earlier stock H-D® models
equipped with a single cable throttle mechanism must be converted to the two cable, pull open-pull closed type. S&S oers these throttle assemblies but
does not include them with any carburetor kit because of the multitude of chassis designs and tment requirements.
Single, braided wire cable throttle mechanisms cannot mechanically close the throttle. If throttle inadvertently sticks in open position,
loss of control of motorcycle and personal injury to operator or others may result.
1980 and Earlier Motorcycles


1981 to Present Big Twin Models




See Picture 2.


1981 to Present Harley-Davidson® Sportster® Models


Chart 1)
Picture 2
S&S® THROTTLE CABLE APPLICATION CHART
Length
Total Housing
Length
Vinyl Housing
Part Number
Open Side
Part Number
Close Side
Fitment
  19-0430 19-0431 
  19-0432 19-0433



  19-0436 19-0437 
  19-0434 


  19-0438 19-0439


  19-0446 19-0447 
  19-0440 19-0441 
  19-0462 19-0463 
  19-0464  
Chart 1