Product data
62 ULTRA Series
Publication 1398-2.0 - August 1999
24V Sourcing I/O Conversion Card (9103-0152) and Cables
The 24V I/O conversion card converts the 16 internal inputs and 6 internal
outputs from an active low state to an active high state. It must be mounted in
the same enclosure as the ULTRA Plus. By adding this component, you
comply with the European Union Low Voltage Directive (LVD).
To connect your ULTRA Plus drive to the I/O conversion card, you can use
the following optional cables:
• Part number 44-0141-003 (3-ft cable)
• Part number 44-0141-010 (10-ft cable)
Note: The conversion card cables are not required for CE compliance.
AC Line Filters
AC line filters are required for EMC compliance.
1
For multiple drives using one filter, the combined drive input currents must not exceed filter current rating.
Part Number Description ULTRA Plus
9101-1517 10A, 1φ 1398-PDM-10
9101-1518 23A, 1φ 1398-PDM-20
9101-1387 36A, 1φ 1398-PDM-30
9101-1388
1
50A, 1φ For multiple drives using one filter
9101-1389 36A, 3φ 1398-PDM-75
9101-1390
1
80A, 3φ For multiple drives using one filter