Product data

64 ULTRA Series
Publication 1398-2.0 - August 1999
ULTRA Plus Transformer (0020-5093) and Power Supply (9101-0120)
for 1398-PDM-25, -50, -100, and -150
Power Supply Module Selection Guidelines (1398-PSM-25, -50, -100,
and -150)
1398-PSM power supply modules should be selected based on the PSM rating
required by your application. Up to six standard systems can be operated
from a single power supply module. To select power supply modules:
1. Select the appropriate standard system(s) for your application.
2. Determine the total PSM rating by adding the PSM rating of each system
chosen.
3. Select the power supply module with a PSM model number greater than
your application total or select multiple PSMs, as required.
For example, if your application uses the following:
your total PSM rating is 65. The 1398-PSM-125 with a PSM rating of 125 is
the power supply module that you need for your application.
ULTRA PLUS TRANSFORMER / POWER SUPPLY
Auxiliary power supply to maintain logic voltages when 3-phase power is turned off.
9101-0120 Auxiliary Logic Supply
P9
(4)
Transformer 0020-5093
Isolation Transformer
for Auxiliary Logic Supply
Note: Isolation Transformers are not
required for operation but may be
helpful in reducing electrical noise.
Includes four 2m (6 ft) cables
Quantity Motor Drive PSM Rating
1 H-8350-S-H00AA 1398-PDM-100 45
1 H-6200-Q-H00AA 1398-PDM-100 20
1398-PSM-50
Power
Supply
50A continuous
Shunt power
Continuous: 0.6 kW
Peak: 20 kW
1398-PSM-125
Power
Supply
100A continuous
Shunt power
Continuous: 1.2 kW
Peak: 40 kW