Specifications

! Address to Translate contains the address to translate. If the logical block format is specified, the
first four bytes of the field (bytes 6 to 9) contain the LBA and the remainder must be zero. For the
physical format the address must be specified as follows.
Sector Number or Bytes from Index10-13
Head Number9
Cylinder Number6-8
01234567
Bit
Byte
Figure 161. Address to translate
8.34.3 SEND DIAGNOSTIC Page 80
This requests the drive to perform off-line read scan.
(MSB) Off-line Immediate Time
(LSB)
6
7
Reserved = 0
5
SMART Revision = 03h
4
Page Length = 04h2-3
Reserved = 01
Page Code = 80h0
01234567
Bit
Byte
Figure 162. SEND DIAGNOSTIC Page 80
! Off-line Immediate Time specifies the delay to start the off-line read scan in seconds. When this
value is zero, the drive immediately starts the off-line read scan.
Ultrastar 146Z10 hard disk drive specifications
160