Page 128
P108 Far Blanking Distance
This is the distance (as a percentage of empty level P105) beyond the
empty point that the unit will be able to measure, and by default is pre-set to
20% of the empty level.
If the surface being monitored can extend beyond the Empty Level (P105)
then the far blanking distance can be increased to a maximum of 100% of
empty level.
This parameter is always entered as a % of empty level.
Relay Parameters
Relay ParametersRelay Parameters
Relay Parameters
All relay related parameters are prefixed with a 2**.
The second digit of the three figure parameter number denotes the relay
number as follows:
21* parameters for Relay 1
22* parameters for Relay 2
23* parameters for Relay 3
The third digit selects specific parameter for the setting of the relays, which
can be selected individually and results in the following parameter numbers
for each relay.
Relay 1 210 to 219
Relay 2 220 to 229
Relay 3 230 to 239