CY3280-MBR3 Evaluation Kit User Guide, Doc. #: 001-89905 Rev. *B 53
Configuration Files and Example Projects
6. Ensure that the I
2
C selection jumpers J13 and J14 are shorted between pins 1 and 2 to allow
communication with the PSoC 5LP onboard USB-I
2
C bridge.
7. Connect the kit to the EZ-Click 2.0 customizer tool using the following steps.
a. Click the Select Target Device button ( ) on the tool bar of EZ-Click 2.0.
b. Select 3.3 V as target power and 400 kHz as I
2
C speed; click OK to connect to the CY3280-
MBR3 EVK, which has the slave address of 0x37.
Figure 5-3. Connecting the Kit with the Customizer
8. Select Apply Current Config in the Configuration menu to apply the configuration to the kit, as
illustrated in Figure 5-4.
Figure 5-4. Apply Current Configuration
9. Wait until the message “Device configuration completed successfully” appears on the status bar
at the bottom of the EZ-Click window, as displayed in Figure 5-5.