Specifications

Elite Series Technical Manual PDL Part No. 4201-180 Rev J
43
9 THE DEFAULT SCREEN LIST
The Elite Series provides as a default a very flexible set of formats and functions for control inputs and outputs.
The Elite Series can be operated in Open Loop mode as a speed controller, or in Closed Loop mode as a torque or speed controller.
The Screen List available in the default configuration is shown in Figure 9.1.
4808-049 Rev. L
RUN t+100% S +100%
A1 LOCAL MODE=SP
A2 LOCAL TQ= +0.0%
A3 LOCAL SP=+100.0%
A4 TQ=+100%SP=+100%
A5 +7.5kW +1480RPM
A6 +16A +50.0Hz
A7 Tm=100% Ti=100%
A8 565Vdc 400Vac
C COMPARATOR
C1 COMP1 SEL= 02
C2 1 ON= +100%
READ-WRITE
READ ONLY
HIDDEN
MOTOR TEMP
ANALOG IN 2
ANALOG IN 1
FIBRE IN
ANALOG IN 1+2
INVERTER TEMP
PROCESS ERROR
PROCESS FB
PROCESS REF
OUTPUT CURR
FULL SCALE
REF TORQUE
REF SPEED
MOTOR TORQUE
MOTOR SPEED
MOTOR POWER
BUS VOLTAGE
OUTPUT VOLTS
NULL
C3 to +250%
-250% to C2
4800/9600
OFF /1200/2400/
1 to 240
1s/5s/25s/OFF
DEVICENET
MODBUS
OFF/1to100%
0 to 250sec
-250% to C5
C6 to +250%
H4 DEVICENET
H3b BAUDRATE= 9600
H3a COMMS ADR= 10
H3 MODBUS
H2 COMM T/O= OFF
H1 PROTOCOL = M
H SERIAL COMMS
D2 DB DUTY= OFF
D1 DB TIME= 10s
D DYNAMIC BRAKE
C6 2 OFF= + 90%
C5 2 ON= +100%
C4 COMP2 SEL= 02
C3 1 OFF= + 90%
F6 CLEAR HIST = N/Y
F5 NO FAULTS
F4 NO FAULTS
F3 NO FAULTS
F2 NO FAULTS
F1 NO FAULTS
F NO FAULTS
H4a Mac ID= 63
H4b Baud= 125kbps
H4c Ass In= 70
H4d Ass Out= 20
H4e CTRL SRC= 00
H4f REF SRC= 00
DNET REF
LOCAL REF
1/2/3/4/5/20/21/100
DNET DECIDES
LOCAL CTRL
DNET CTRL
DNET DECIDES
50/51/52/53/54/60/61/
125/250/500kbps
0 to 63
H3c PARITY= EVEN EVEN/ODD/NONE
A6a O/P CURRENTS
70/71/101
A7a TH= Ti=
H4g DNET STATUS
Figure 9.1a: Screen List A-H