SCREEN GROUP A: STATUS DISPLAYS
RUN t+100% S +100%
A1 LOCAL MODE=SP
A2 LOCAL TQ= +0.0%
A3 LOCAL SP=+100.0%
A4 TQ=+100%SP=+100%
A5 +7.5kW +1480RPM
A6 +16A +50.0Hz
A7 Tm=100% Ti=100%
A8 565Vdc 400Vac
READ-WRITE
READ ONLY
HIDDEN
4808-072 Rev C
A6a O/P CURRENTS
A7a TH= Ti=
A1 LOCAL CONTROL MODE
Screen LOCAL MODE=SP
Description LOCAL KEYBOARD MODE SELECT
Range SPEED/TORQUE
Default Value SPEED
OFF to Modify NO
Attribute Read Only
FUNCTION Sets the operating mode of the Elite Series if
not otherwise selected (i.e., as a Multi-
function input. Refer Screen I7a).
SETTING UP Select the desired operating (speed or
torque) mode.
Note: The selected mode is indicated on the Status
Screen by means of a uppercase “S” (speed
mode) or uppercase “T” (torque mode).
A2 LOCAL TORQUE REFERENCE
Screen LOCAL TQ=+0.0%
Description LOCAL TORQUE REFERENCE
Range -250% to +250%
Units % OF MOTOR RATED TORQUE
Default Value 0%
OFF to Modify NO
Attribute Read-Write
FUNCTION Local keyboard control of reference torque.
SETTING UP The reference torque source (Screen I3 or
I5) must be set to LOCAL before this screen
has an effect. Although it can be adjusted to
±250% of motor rated torque, the reference
torque is constrained between the minimum
and maximum torque (set by Screens L4 and
L5).
A3 LOCAL SPEED REFERENCE
Screen LOCAL SP=+100.0%
Description LOCAL SPEED REFERENCE
Range -250% to +250%
Units % OF MOTOR RATED SYNCHRONOUS
SPEED
Default Value 100%
OFF to Modify NO
Attribute Read-Write
FUNCTION Local keyboard control of reference speed.
SETTING UP The reference speed source (Screen I2 or I4)
must be set to LOCAL before this screen has
an effect. Although it can be adjusted to
±250% of motor rated synchronous speed,
the reference speed is constrained between
the minimum and maximum speeds (set by
Screens L2 and L3).
A4 REFERENCE TORQUE, REFERENCE
SPEED
Screen TQ=+100.0% SP=+100%
Description TORQUE REFERENCE, SPEED
REFERENCE
Range -250% TO +250%;
-250 TO +250%
Units % OF MOTOR RATED TORQUE;
% OF MOTOR RATED SYNCHRONOUS
SPEED
Attribute Read Only
FUNCTION Shows reference torque and speed. This
screen is displayed after power up or external
reset.
A5 MOTOR POWER, MOTOR RPM
Screen +7.5kW +1480RPM
Description MOTOR POWER, MOTOR RPM
Range -999kW TO +999kW;
-12000RPM TO +12000RPM
Units kW - KILOWATTS;
RPM - REVOLUTIONS PER MINUTE
Attribute Read Only
FUNCTION Shows estimated motor power and motor
speed in revolutions per minute (RPM). In
Open Loop Mode and V/Hz control modes,
the speed will be estimated.
SETTING UP The motor rated kW (Screen N4) and rated
RPM (Screen N5) must be entered for correct
calibration of this screen.
A1
A2
A3
A4
A5