Datasheet
Table Of Contents
- 1. General Description
- 2. Electrical Characteristics
- 3. SX1272/73 Features
- 4. SX1272/73 Digital Electronics
- 4.1. The LoRaTM Modem
- 4.2. FSK/OOK Modem
- 4.2.1. Bit Rate Setting
- 4.2.2. FSK/OOK Transmission
- 4.2.3. FSK/OOK Reception
- 4.2.4. Operating Modes in FSK/OOK Mode
- 4.2.5. General Overview
- 4.2.6. Startup Times
- 4.2.7. Receiver Startup Options
- 4.2.8. Receiver Restart Methods
- 4.2.9. Top Level Sequencer
- 4.2.10. Data Processing in FSK/OOK Mode
- 4.2.11. FIFO
- 4.2.12. Digital IO Pins Mapping
- 4.2.13. Continuous Mode
- 4.2.14. Packet Mode
- 4.2.15. io-homecontrol® Compatibility Mode
- 4.3. SPI Interface
- 5. SX1272/73 Analog & RF Frontend Electronics
- 6. Description of the Registers
- 7. Application Information
- 8. Packaging Information
- 9. Revision History

www.semtech.comPage 83
SX1272/73
WIRELESS, SENSING & TIMING DATASHEET
Rev. 2 - July 2014
©2014 Semtech Corporation
Notes - For +20 dBm restrictions on operation please consult the following section.
- To ensure correct operation at the highest power levels ensure that the current limiter OcpTrim is adjusted to
permit delivery of the requisite supply current.
- If the PA_BOOST pin is not used it may be left floating.
5.4.3. High Power +20 dBm Operation
The SX1272/73 has a high power +20 dBm capability on PA_BOOST pin, with the following settings:
Table 32 High Power Settings
Notes - High Power settings must be turned off when using PA0
- The Over Current Protection limit should be adapted to the actual power level, in RegOcp
Specific Absolute Maximum Ratings and Operating Range restrictions apply to the +20 dBm operation. They are listed in
Tab le 33 and Ta bl e 34.
Table 33 Operating Range, +20 dBm Operation
Table 34 Operating Range, +20 dBm Operation
The duty cycle of transmission at +20 dBm is limited to 1%, with a maximum VSWR of 3:1 at antenna port, over the
standard operating range (-40 to +85 °C). For any other operating conditions, contact your Semtech representative.
Register Address
Value for
High Power
Default value
PA0 or +17dBm
Description
RegPaDac 0x5A 0x87 0x84
High power PA control
Symbol Description Min Max Unit
DC_20dBm Duty Cycle of transmission at +20 dBm output - 1 %
VSWR_20dBm Maximum VSWR at antenna port, +20 dBm output - 3:1 -
Symbol Description Min Max Unit
VDDop_20dBm Supply voltage, +20 dBm output 2.4 3.7 V