REV.2011.7.22 80 SERIES Advanced Remote Starters & Vehicle Security Systems TM INSTALLATION GUIDE AUTOMATIC AND MANUAL TRANSMISSION MODELS* *MUST USE M SERIES REMOTE STARTER! WARNING: NEVER USE AN AUTOMATIC TRANSMISSION STARTER IN A MANUAL TRANSMISSION VEHICLE! www.ultrastarters.com FCC ID NOTICE This device complies with Part 15 of the FCC rules. Operation is subject to the following conditions: 1. This device may not cause harmful interference, and 2.
80 SERIES PAGE 2 INSTALL MANUAL SYSTEM PROGRAMMING - Menu 1 TABLE OF CONTENTS QUICK VIEW WIRING DIAGRAM..........................................................3-4 Connector Pin Configuration Antenna Connector Park Light Jumper INSTALLATION NOTES............................................................................5 TACH LEARNING......................................................................................6 Tach/ Tachless Learn Hybrid Mode QUICK VIEW PROGRAMMING.........................
80 SERIES PAGE 3 QUICK VIEW WIRE DIAGRAM SYSTEM PROGRAMMING - Menu 1 INSTALL MANUAL OUTPUT TO ACTIVATE THE STARTER CIRCUIT YELLOW OUTPUT TO ACTIVATE THE ACCESSORY CIRCUIT GREEN 12VOLT/ 30 AMP MAIN POWER INPUT RED 12VOLT/ 30 AMP MAIN POWER INPUT SELECTABLE OUTPUT* (DEFAULT 2ND IGN) RED OUTPUT TO ACTIVATE THE IGNITION CIRCUIT BLUE (-) HORN OUTPUT/ (+) SIREN OUTPUT (ALARM MODELS) BROWN** (-) STARTER KILL/ ANTI-GRIND OUTPUT SELECTABLE PARK LIGHT OUTPUT (DEFAULT POSITIVE) ORANGE SYSTEM GROUND I
80 SERIES PAGE 4 INSTALL MANUAL SYSTEM PROGRAMMING - Menu 1 QUICK VIEW WIRE DIAGRAM OUTPUT TO ACTIVATE DOOR LOCK CIRCUIT (-) GREEN OUTPUT FOR VOLTAGE INVERTER* N/A* OUTPUT TO ACTIVATE DOOR UNLOCK CIRCUIT (-) BLUE PRE-WARN TRIGGER FOR ALARM MODELS (-) BLUE** FULL TRIGGER FOR ALARM MODELS (-) GREEN** GROUND OUTPUT FOR ADDITIONAL SENSOR (-) BLACK** 12VOLT OUTPUT FOR ADDITIONAL SENSORS (+) RED** (-) WHILE RUNNING OUTPUT (BYPASS TURN ON) GROUND OUTPUT FOR BYPASS MODULE WHT/VIOLET 12VOLT OUTPU
PAGE 5 NOTES PROGRAMMING - Menu 1 SYSTEM 80 SERIES INSTALL MANUAL PLEASE NOTE * THE CENTRE PIN OF THE KEYLESS CONNECTOR IS LOW CURRENT AND IS DESIGNED TO SUPPLY POWER TO DOOR LOCK MODULES (DO NOT CONNECT TO RELAYS) OVERLOADING THIS OUTPUT WILL DAMAGE THE MODULE! **THIS CONNECTOR IS USED FOR ALARM MODELS ONLY. A GROUND PULSE TO THE BLUE WIRE WILL CAUSE THE ALARM TO BEEP 3 TIMES. A GROUND PULSE TO THE GREEN WIRE WILL CAUSE THE ALARM TO ACTIVE FOR 60 SECONDS.
80 SERIES PAGE 6 INSTALL MANUAL SYSTEM - Menu 1 SYSTEMPROGRAMMING WIRING DETAILS AUTO TACH/ TACHLESS LEARNING Start the vehicle with the ignition key. 2 CHIRPS/ 2 FLASHES = TACH MODE 3 CHIRPS/ 3 FLASHES = DATA TACH MODE 4 CHIRPS/ 4 FLASHES = TACHLESS MODE NOTES: When tach learning the system first sends out a request for tach from the data port. If it gets a valid rpm response over 750 rpm then it goes into data tach mode (3 flashes).
80 SERIES PAGE 7 PROGRAM MODE SYSTEM PROGRAMMING - Menu 1 INSTALL MANUAL ENTERING PROGRAM MODE 1 - Cycle the Ignition Key On/Off On/Off On (Leaving the key ON) 2 - Press and release the Program Switch 1 time. The park lights will turn on and the Horn (optional/ Siren (alarm model) will chip to confirm program mode entered. 3 - Select the Program Menu by pressing...
0 SERIES PAGE 8 INSTALL MANUAL PROGRAM MODE PROGRAM MODE 1 SYSTEM PROGRAMMING - Menu 1 PROGRAM MODE 1 (1 Flash/ 1 Chirp) SETTING # LED FLASHES SETTING DESCRIPTION OPTION 1 1 CHIRP OPTION 2 2 CHIRPS OPTION 3 3 CHIRPS 1 IGNITION AUTO-LOCK IGNITION AUTO-LOCK / UNLOCK IGNITION AUTO-LOCK ONLY IGNITION AUTO-LOCKS DISABLED 2 HORN / SIREN SETTINGS HORN / SIREN CHIRPS DISABLED HORN/SIREN CHIRPS ENABLED 3 DOOR LOCK PULSE OPTIONS DOUBLE UNLOCK & SINGLE LOCK DOUBLE LOCK & SINGLE UNLOCK SINGLE LO
80 SERIES PAGE 9 PROGRAM MODE SYSTEM PROGRAMMING - Menu 1 PROGRAM MODE 3 INSTALL MANUAL SYSTEM PROGRAMMING - Menu 1 PROGRAM MODE 3 (3 Flashes/ 3 Chirps) SETTING # LED FLASHES SETTING DESCRIPTION OPTION 1 1 CHIRP OPTION 2 2 CHIRPS OPTION 3 3 CHIRPS 1 SELECTABLE RELAY 2ND STARTER 2ND ACCESSORY 2ND IGNITION 2 SPECIAL DOOR LOCK OPTIONS UNLOCK BEFORE / LOCK AFTER START LOCK AFTER STARTER SHUT OFF NO ADDITIONAL PULSES 3 GAS / DIESEL MODE NEG GLOW PLUG / 30 SEC DELAY TRIGGER TO START 2 POSITI
80 SERIES INSTALL MANUAL PAGE 10 SYSTEM - Menu 1 SYSTEMPROGRAMMING WIRING DETAILS 6-PIN CONNECTOR OUTPUT TO ACTIVATE START CIRCUIT YELLOW OUTPUT TO ACTIVATE ACCESSORY/ HEATER CIRCUIT GREEN 30A HIGH CURRENT 12VOLT INPUT RED 30A HIGH CURRENT 12VOLT INPUT RED SELECTABLE OUTPUT (DEFAULT SECOND IGNITION) WHITE* OUTPUT TO ACTIVATE IGNITION CIRCUIT BLUE 4-PIN CONNECTOR (+) SIREN/ HORN OUTPUT (-) BROWN STARTER-KILL/ ANTI-GRIND OUTPUT ORANGE JUMPER SELECTABLE PARK LIGHT OUTPUT (+ OR -) WHITE SY
PAGE 11 SYSTEMPROGRAMMING WIRING DETAILS SYSTEM - Menu 1 80 SERIES INSTALL MANUAL PIN-1 YELLOW Starter Output-This wire will test 0V when the key is off, in the Accessory position and when the Ignition is in the on position. The starter wire is 12volts during the start/ crank position only. PIN-2 GREEN Heater/Acc Output-This wire will test 0V when key is off, 12volts in the ACC and IGN positions and off during start/ crank position.
80 SERIES INSTALL MANUAL PAGE 12 SYSTEM SYSTEMPROGRAMMING WIRING DETAILS- Menu 1 13 PIN CONNECTOR OUTPUT FOR FACTORY ALARM RE-ARM OUTPUT FOR FACTORY ALARM DIS-ARM NEGATIVE STARTER OUTPUT OUTPUT FOR TRUNK RELEASE ACTIVATION NEGATIVE ACCESSORY OUTPUT/ AUXILIARY OUTPUT 2 AUXILIARY OUTPUT 1/ PROGRAMMABLE OUTPUT BRAKE SWITCH INPUT (+) WHEN BRAKE IS PRESSED YELLOW BROWN GRAY RED/WHT ORG/WHT WHT/VIO PINK PARK BRAKE INPUT. M SERIES REMOTE STARTER ONLY.
PAGE 13 SYSTEMPROGRAMMING WIRING DETAILS- Menu 1 SYSTEM 80 SERIES INSTALL MANUAL 1-YELLOW Re-arm(-) (Programmable) - Supplies one .75 second pulse when locked and one .75 second pulse after remote start shutdown. Factory alarm re-arm/ RAP shutdown. 2-BROWN Dis-arm(-) - .75 second pulse when unlock button is pressed and one .75 second pulse before remote start activation. For factory alarm dis-arm/ “wake up”. 3-GRAY (-) Start/ Crank - Negative output during crank/ start.
80 SERIES PAGE 14 INSTALL MANUAL SYSTEM SYSTEMPROGRAMMING WIRING DETAILS- Menu 1 4 PIN AUXILIARY SENSOR CONNECTOR* *ALARM MODELS ONLY PRE-WARN TRIGGER BLUE FULL TRIGGER INPUT GREEN GROUND OUTPUT FOR AUXILIARY SENSOR BLACK 12VOLT OUTPUT FOR AUXILIARY SENSOR RED 1- BLUE Pre-Warn Trigger (-) Input When this wire is grounded by an auxiliary sensor (i.e: Radar Sensor) the system will chirp the SIREN 3 times. 2- GREEN Full Alarm Trigger (-) Input When this wire is grounded by an auxiliary sensor (i.
80 SERIES PAGE 15 SHOCK SENSOR PROGRAM SYSTEM PROGRAMMING - Menu 1 INSTALL MANUAL ALARM MODELS ONLY 1 - ENTER SHOCK SENSOR ADJUSTMENT MODE + Press & HOLD Lock + Unlock buttons at the same time 3 CHIRPS Continue to hold the buttons for 3-5 seconds until the SIREN Chirps 3 times (Note: System will Arm or Disarm via silent arming prior to entering adjustment mode) 2 - ADJUSTING THE SHOCK SENSOR Each time the lock button is pressed and released the sensitivity will INCREASE by 1 level.
80 SERIES PAGE 16 INSTALL MANUAL SYSTEM PROGRAMMING - Menu 1 TRANSMITTER PROGRAMMING SYSTEM PROGRAMMING - Menu 1 The system can lean up to 4 different remote’s. Each remote to be used MUST be programmed together during the same sequence. For security, when a new remote is programmed all previous remote’s are deleted. Please see remote operation chart for information on using Second Car / Pad Lock Operations.
80 SERIES PAGE 17 DIAGNOSTICS SYSTEM PROGRAMMING - Menu 1 INSTALL MANUAL DIAGNOSTICS CHART If the remote starter does not activate when the start button is pressed the park lights will flash a diagnostic to indicate what shutdown input has been triggered. For example: If the start button is pressed the park lights flash 3 times slowly.
80 SERIES PAGE 18 INSTALL MANUAL RELAY DIAGRAMS DOOR LOCK DIAGRAMS To Control Relay or Actuators Alarm and / or Starter Module NEGATIVE DOOR LOCK (LOW CURRENT) Vehicle's Lock/Unlock Switch Door lock Output Green Blue Ground 87 Alarm and / or Starter Module NEGATIVE DOOR LOCK (LOW CURRENT) Door lock Output 87a Green 86 Vehicle's Lock/ Unlock Switch 12volts 85 30 Blue Ground 87 87a 86 12volts 85 30 USE SPDT 12v Relay Alarm and / or Starter Module POSITIVE DOOR LOCK (LOW CURRENT) Vehi
80 SERIES PAGE 19 RELAY DIAGRAMS SYSTEM PROGRAMMING - Menu 1 INSTALL MANUAL DOOR LOCK DIAGRAMS Ground Alarm and / or Starter Module NEGATIVE ONE WIRE DOOR LOCKS Vehicle's Lock/ Unlock Switch 87 Door lock Output 87a Green 86 12volts 85 30 Blue Ground Lock Resistor 87 87a 86 12volts 85 Unlock Resistor 30 USE SPDT 12v Relay Alarm and / or Starter Module REVERSE POLARITY DOOR LOCK SYSTEM 12volts 87 Door lock Output 87a Green x 86 30 Blue 12volts 87 87a x x 30 USE SPDT 12v Relay
80 SERIES PAGE 20 INSTALL MANUAL **FOR DETAILED VEHICLE WIRING INFORMATION GO TO: http://www.ultrastarters.com/wiring_diagrams.html This site is for registered and authorized dealer only. If you are an authorized dealer but have been registered, please fill out the service request form at http://www.ultrastarters.com/wiring_diagrams.html PRODUCT INFORMATION: www.ultrastarters.com TECHNICAL SUPPORT: support@ultrastarters.com ORDERING: orders@ultrastarters.