Manual

CH0007 Operation Manual
Newark, New York
|
315-332-7100
|
Fax: 315-331-7800
©2010 Ultralife Corporation • www.ultralifecorp.com • All specific subject to change without notice
The information contained herein is for reference only and does not constitute a warrant of performance • 30 SEP 10 UBI-5166 Rev: A
Page 22 of 25
6 SPECIFICATIONS
6.1 Physical Characteristics
Dimension Measurement
Width 8.4 inches (21.3 cm) (Including mounting brackets)
Length 27.3 inches (69.3 cm)
Height 14 inches (35.6 cm)
Weight without Cables
and Batteries
36 Lb. (16.3 kg)
Color Olive Drab Green
Case CARC coating - MIL-DTL-64159
Display VFD graphical and LED status displays
Controls On/Off Toggle Switch, Conditioning Override toggle switch, VFD brightness tog
switch
Typical Charge Time
(UBBL03)
< 2.5 Hours
Mounting Mounting rails integrated on back of charger
External
Communication
USB port for software upgrades and remote monitoring (Additional software and
P
required)
Battery Communication
SMBUS V1.1 w/ PEC (Packet Error Protection)
SMBUS Charger Level 3 Compliant
6.2 Electrical Characteristics
Dimension Measurement
Charger Input Range 21 to 32 volts DC (Low Power Alarm below 22V)
Charger Input Current 40 to 90 Amps (Circuit Breaker Protected at 75A)
Maximum Battery Charge Current 5A
Minimum Battery Charge Current 0.3A
Maximum Charge Voltage 16.8V
Maximum Conditioning Discharge Current 2A
Power Standard MIL-STD-1275 compliant