SureFire Digital Airburst Slave Module Addressing
Airburst 48 channel slave modules should occupy 3 consecutive Encoder numbers. This is selectable 
by the encoders.
48-channel Airburst slaves and 16-channel slaves can be congured to run from the same controller 
so long as there is no address conict.
Important Note
Pyro Logic Controller SureFire Slave Module Safe Field Operation Procedure
Read and familiarize yourself with the operators manuals for these products. If there is something 
you do not understand about the addressing and operation of the SureFire system, consult qualied 
personnel.
DO NOT connect ANY pyro devices to the system prior to running the following steps. You run the 
risk of injury or death to yourself and your co-workers.
1.  Place all slave modules in position. The system is designed for modules to be placed in close 
proximity to the pyrotechnic eects to avoid long runs of cable from the channel outputs to the 
pyro eects or matches.
2.  In the case of regular eects, keep the modules at least six feet from the eect. Dust and debris 
from these eects may eect the operation of the slave modules over the long term.
3.  In the case of ‘concussion’ eects, place the modules at least 15 feet from the concussion pots. 
The shock from the concussions can damage the electronics of the module and/or shake the 
communication or AC connections loose.
4.  Run all communication and AC cables to the modules.
5.  Set up the PyroLogic controller.
6.  Plug all communication cables into the controller.
7.  With the SAFE/ARM key in the SAFE position and the SLAVE POWER key in the OFF position, recall 
the show you intend to run.
8.  All slaves should be powered on and all 16 Red channel LEDs should be lit. The Green Power LED 
should be lit. The Yellow scan LED should NOT be lit. (See Trouble Shooting).
9.  From the controller, identify all on line modules by turning the encoder. On-line modules will 
show all 16 green match LEDs lit when the module select knob is turned to the address of the 
module.
10. Turn the SLAVE POWER key switch ‘ON’. Firing and match test current is now applied to all module 
output channels. This test conrms communication between the controller and all slave mod-
ules. 
11. Investigate each slave for faults. All 16 Red channel LEDs should be o. (If there are any Red 
channel LEDs still lit, see trouble shooting). The Green Power LED and the Yellow scan LED should 
be lit. (See Trouble Shooting).