How to Guide

ClarkDietrich Building Systems has prepared this literature with the utmost
diligence and care for accuracy and conformance to standards.
ClarkDietrich intends this information to be accurate, informative, and helpful
as a selection guide for choosing ClarkDietrich Building System products.
However, this information is only to be used for guidance and is not intended
to replace the design, drawings, specifications, and decisions of a professional
architect or engineer.
ClarkDietrich Building Systems or its affiliates shall not be responsible for
incidental or consequential damages, directly or indirectly sustained, nor for
loss caused by application of our products for other than their intended uses.
Our liability is limited to replacement of defective products. Claims shall be
deemed waived unless they are made to us in writing within thirty (30) days
of the date a problem was or reasonably should have been discovered.
ClarkDietrich Building Systems reserves the right to modify or change any
information contained in this literature without notification.
UL
®
and UL
®
Design are service marks of Underwriters Laboratories, Inc.
AISI S100-07 North American Specification for the Design of
Cold-Formed Steel Structural Members
AISI S220-11 North American S
tandard for Cold-Formed Steel
Framing—Nonstructural Members
ASTM American Society for Testing and Materials
A1003 "Material specification for steel sheet mechanical and chemical requirements"
C645 "Standard Specification for Nonstructural Steel Framing Members"
C754 "Standard Specification for Installation of Steel Framing Members to Receive
Screw-Attached Gypsum Panel Products"
C1002 "Standard Specification for Steel Self Piercing Tapping Screw for the Application
of Gypsum Panel Products or Metal Plaster Bases to Wood Studs or Steel Studs"
E119 "Standard Test Methods for Fire Tests of Building Construction and Materials"
E72 "Standard Test Methods of Conducting Strength Tests of Panels for
Building Construction"
E90 "Standard Test Method for Laboratory Measurement of Airborne Sound
Transmission Loss of Building Partitions and Elements"
UL
®
Underwriters Laboratories
testing standard
UL 263 "Fire Tests of Building
Construction and Materials"
Multiple UL
®
design
listings for ProSTUD
Over 50 UL Designs. See UL file number
R26512 for additional information.
Independent product
testing and certification
Sound ratings: (WEAL) Western
Electro-Acoustic Laboratory
Fire testing: (UL) Underwriters Laboratories Inc.
Additional code approvals
SFIA (Steel Framing Industry Association)
ATI CCRR-0207
ProSTUD
®
& ProTRAK
®
CODE APPROVALS AND PERFORMANCE STANDARDS
ClarkDietrich
ProSTUD Drywall Framing System meets or exceeds these applicable performance standards.
USGBC and related logo is a
trademark owned by the U.S.
Green Building Council and is
used by permission.
LEED
®
Credit MR 2
Construction Waste Management (Up to 2 points)
ClarkDietrich products are manufactured from cold-formed
steel. Steel is 100% recyclable, which helps divert debris
from the waste stream. The contribution to LEED must
be calculated by the contractor based on weight or volume.
LEED Credit MR 4 Recycled Content (Up to 3 points)
ClarkDietrich Building Systems produces products with a
minimum recycled content of 34.9%, of which 24.3% is post-
consumer and 9.4% is pre-consumer. These minimum values are
based on resources from Steel Recycling Institute. If a higher
content is desired, ClarkDietrich can provide this information if
mill certifications are requested at time of order. ClarkDietrich
recycles nearly 100% of its post-industrial scrap.
Scan for the most up-to-date
ClarkDietrich literature.
21
ClarkDietrich Building Systems is a proud member of
the Steel Framing Industry Association (SFIA). Check
the updated list of Certified Production Facilities at
Architectural Testing's website at www.archtest.com.
The technical content of this literature is eective 4/9/15 and supersedes all previous information. Pub. No. CD-ProSTUD 4/15
clarkdietrich.com
LOCATIONS
ClarkDietrich Building Systems
Manufacturing and Sales Locations:
CALIFORNIA Riverside
P 951.360.3500
F 951.360.3333
CALIFORNIA Sacramento
P 951.360.3500
F 951.360.3333
CONNECTICUT Bristol
P 866.921.0023
F 860.584.6899
FLORIDA Dade City
P 352.518.4400
F 352.518.4450
CLIP EXPRESS
East
P 866.638.1908
CLIP EXPRESS—West
P 530.406.3462
VINYL CORP.
P 800.648.4695
GEORGIA McDonough
P 678.304.5500
F 678.304.5555
HAWAII Kapolei
P 951.360.3500
F 951.360.3333
ILLINOIS Rochelle
P 800.659.0745
F 513.645.0750
MARYLAND Baltimore
P 410.477.4000
F 410.477.1550
OHIO Warren—East
P 330.372.5564
F 330.372.4055
OHIO Warren—West
P 330.372.4014
F 330.372.1945
TEXAS Baytown
P 281.383.1617
F 281.573.1679
TEXAS Dallas
P 214.350.1716
F 214.350.7252
ClarkDietrich Engineering Services.
A full spectrum of solutions.
Toll-Free Phone: 877.832.3206
Toll-Free Fax: 877.832.3208
Technical Services: 888.437.3244
Email: engineering@clarkdietrich.com
CENTRAL Crown Point, IN
NORTHEAST Bristol, CT
SOUTHEAST McDonough, GA
SOUTHEAST Roswell, GA
WEST Carlsbad, CA