Installation Guide
21
Fitting Assembly
Step 6 Attach ange nut to the installed HOME-FLEX®
tting
Place the HOME-FLEX® ange nut onto the
installed tting. Hand tighten the tting
assembly from the nut-end, then tighten to
the recommended torque value of 62 lbft
(generally, tighten with force until the nut
will no longer turn) using a second wrench
to hold the tting in place.
DO NOT use sealant on the parallel thread
of the socket.
Termination Fittings (Parts 11-464-XXX)
Termination Flange
Tubing
Retainer Ring
Fitting
Step 1 Cut HOME-FLEX® tubing to length
Route CSST through structure to the desired
location of the termination ange. Bend
tubing as required so it exits the structure in
desired direction of the termination plate.
Cut the excess CSST so about 2" of tubing
extends beyond the wall.
Step 2 Remove tubing jacket to prepare for tting
assembly
Using a utility knife, strip the yellow tubing
jacket back 2 valleys from the end of the
tubing. Also remove the yellow warning
label from the tting assembly.
DO NOT use a tube cutter.