KG
KG
Load
Side Load
Transmotec
Transmotec
www.transmotec.com
The load should be centered on the operating direction
Side load is NOT good for the actuator. In case the
actuator rod is exposed to side load the service life time
will be reduced.
Load force up to 1000N
Static force 2300N
Operating temperature -26°C~+65°C
Duty cycle 25% (25% on / 75% off)
2.5 minutes continuous operation followed by 7.5 minutes off
The actuator will extend when the red wire connects to plus and black wire to negative, reverse them for retraction.
Make sure the actuator is not connected electrically when installed.
Make sure you use the correct DC voltage.
Actuator force must not be over loaded. Please refer to the model number and it’s force specication.
To avoid over load disconnect the actuator if the current exceed it’s maximum rating.
The actuator have integrated limit switches that will stop the rod when it reach it’s end position of extraction or retraction.
In order to retract or extract again the supply voltage polarity must be reverted.
Notes
DLA INSTALLATION MANUAL
kg
= Limit switch
KG
KG
Load
Side Load
kg
© Copyright Transmotec
MODEL NO. DESIGNATIONS
DLA 12 20 A 200 POT-IP65
Type Voltage
12V DC
24V DC
Gear Ratio
10:1
40:1
ACME
(screw
standard)
Stroke
50mm
100mm
200mm
300mm
Potentiometer Sensor
and IP-Class 65
(Exact)
10.9:1
42.8:1
Current vs Load
200 400 600 800 1000 1200 1400
5:1
10:1
30:1
40:1
20:1
Speed vs Load
200 400 600 800 1000 1200 1400
50
40
30
20
10
5:1
10:1
30:1
40:1
20:1
Max. Load
Rated Load