Instructions / Assembly

6
Making the Electrical
Connections
WARNING
TO AVOID POSSIBLE ELECTRICAL SHOCK, BE
SURE ELECTRICITY IS TURNED OFF AT THE
MAIN FUSE BOX BEFORE WIRING.
If you feel you do not have enough electrical
wiring knowledge or experience, have your fan
installed by a licensed electrician.
This remote control unit is equipped with 16 code
combinations to prevent possible interference
from or to other remote units. The frequency
switches on your receiver and transmitter have
been preset at the factory. Please recheck to make
sure the switches on the transmitter and the
receiver are set to the same position, any
combination of settings will operate the fan as
long as the transmitter and receiver are set to the
same position. (Figure 9).
Insert the receiver into the mounting bracket
with the flat side of the receiver facing the
ceiling as Figure 10.
1.
(Fig. 11) Motor to eceiver electrical
connections: Connect the black wire from the
fan to black wire marked "TO MOTOR L".
Connect the white wire from the fan to the
white wire marked "TO MOTOR N" from the
receiver. Connect the blue wire from the fan to
the blue wire marked "For Light" from the
receiver. Secure the wire connections with the
plastic wire connecting nuts provided.
(Figure 11) Receiver to house supply wires
electrical connections: Connect the black (hot)
wire from the ceiling to the black wire marked
"AC in L" from he receiver. Connect the white
(neutral) wire from the ceiling to the white wire
marked "AC in N" from the receiver. Secure
the wire connections with the plastic wire
connecting nuts provided.
2.
3.
Figure 10
Receiver
Ceiling
Mounting
Bracket
Figure 9
Frequency Switch
WARNING
THE TAB IN THE RING MUST REST IN THE
GROOVE OF THE HANGER BALL AS FIGURE 7.
FAILURE TO PROPERLY SEAT THE TAB IN THE
GROOVE COULD CAUSE DAMAGE TO WIRING.
Figure 8
Groove
Tab