User manual
WinPC-NC Light Parameter settings
errors are produced in this way. If it should be the case they can be
easily eliminated by switching off the identification function and by
manual adjustment of the correct format.
Ignore movement to zero (PA0,0)
It is a feature of HPGL files that there is usually a PA0,0 command at
the end of the program to move to the coordinate zero point. This can
be suppressed using this parameter if it is not required.
Invert axes
The X and Y-axes and their coordinates can be mirrored
independently of one another for all formats. A changed parameter is
immediately visible in the graphical display.
Turning of X/Y axes
The NC data can be rotated around the zero point, e. g. for a better
placement on the material. Rotation always happens in 90 degree
steps.
Realtime file display
It is possible to obtain a general view of the current program position
during a job by a file display. This display shows in realtime the
actual executed command by a cursor bar during operation. The file
display realtime applies to all formats, excepting postscript format
and shows files of up to 32000 lines.
File display of realtime during a job
- 46 -