User manual
WinPC-NC Light Initial start-up with the machine
The machine has to move backwards when arrow keys showing to
the top.
The Z-axis moves down when
arrow keys showing downwards.
For a direction reversal of one axis
it is only necessary to change the
parameter INVERT MOVE
DIRECTION.
i
The move directions to be determined are always relating to the
movement of the tool above the workpiece. Please pay attention
to the correct setting of move directions by mechanics with
moved table. The moved table runs always opposite to the arrow
keys in order to guarantee a correct move direction of the tool
above the workpiece.
5.5. Adjustment of the reference switches
The way of function of the limit and reference switches can easily be
checked with the special function SIGNAL TEST. After activating
this function a window appears with LED display for the most
important inputs.
- 66 -