User manual
WinPC-NC Light Initial start-up with the machine
Error Solution
Axis moves into correct
direction, but very slowly
Switching logic has been adjusted
incorrectly and has to be inverted
and
define the reference switch at the
other end
Axis moves slowly into
correct direction, but stops
on the switch
Switching logic has been adjusted
incorrectly and has to be inverted
and
define the reference switch at the
other end
Axis moves very slowly into
wrong direction
Switching logic has been adjusted
incorrectly and has to be inverted
5.8. Additional steps
The most important tasks have been finished by connecting the
machine and setting the paramaters. Additional actions are
recommended in the following sequence :
1. Determination of the optimal ramps and speeds of all axes by the
special function MOTOR TEST.
2. Determination of further speeds for JOG MOVE and
REFERENCE MOVE by these values.
3. Connecting additional desired and required input and output
signals definable by the signal wizzard.
- 69 -