User manual

WinPC-NC Light Additional Information
Workpiece exceeds working area
The set working area was exceeded during machining of the current workpiece. It
may be possible to rectify this condition by performing reference travel. If not,
either change the unit of measurement,move the zero point or increase the working
area.
Next position outside working area
The current working process has been cancelled because the next position to which
movement should take place is outside the set working area. Correct the settings
and restart the working process.
Unknown command
The NC file contains an unknown command and the working process has therefore
been stopped. It can now be cancelled or continued with the next command.
Cannot create file
WinPC-NC tried unsuccessfully to create a file on the current drive. Either the
drive is not ready or it is full, write protected or you do not have any access rights.
Correct the problem or change to another drive.
No park position defined
You can only move to the park position if you have defined the corresponding
coordinates, i.e. they are set to values other than zero.
Required tools not defined
The working file uses tool numbers which have not yet been defined. The plunge
depth and plunge speed must be defined for every tool, and HPGL files also need
the feed speed to be defined.
Tool moves in too far
The plunge depth of a tool or the depth and the defined feed corrections are deeper
than the maximum plunge depth or the limit of the Z-axis working area.
G code or DIN/ISO syntax error
There is a syntactical error in the G code file being processed. Please use the editor
to correct the line in question and restart the working process.
Maschine positioned on the reference switch
You intend to execute a reference move, however there is at least one axis already
positioned on the reference switch. Start moving back all axes from the switches by
manual operation.
Cannot install file
WinPC-NC tried unsuccessfully to install a file. Possibible causes are insufficient
memory capacity or missing allowance for access in the current register.
•Out of memory
There is insufficient vacant main memory space for processing actions by WinPC-
NC. Please extend the virtual memory in the system control and restart WinPC-NC.
Hardlock error
There is problem with recognizing the USB-dongle. Please remove the dongle, if
necessary, reinstall the drive and insert it into another USB port. Restarting of the
drive is made by calling the file SETUPDRV.EXE in the directory of WinPC-NC.
Incorrect realtime-DLL
There are communcation problems between the actual realtime module and
WinPC-NC which are probably caused by another licence.