User manual

WinPC-NC Economy Additional Information
•HPGL syntax error
There is an invalid HPGL command in the plotter file. It does not correspond to the
syntactical rules and therefore cannot be processed by WinPC-NC.
Connection canceled
The connection to the DLL-controller is interrupted. This can happen when other
window programs or drives interfere with the realtime tasks.
Status stack full/empty
An internal error has occurred in WinPC-NC. Please report this error to the
program authors, providing as many details as possible.
Incorrect parameter
A parameter in the WPI or WPW file is incorrect or the parameter file has been
corrupted.
Stop signal detected
The stop signal has been detected. Please rectify the fault
.
Go to reference position first
WinPC-NC and the controller always need to know what their current position is.
Please always perform reference travel after restarting the program.
Error xx from controller
An internal error has occurred in WinPC-NC during communcation with the
realtime module. Please report this error to the program authors, providing as many
details as possible.
Data cannot be displayed
The NC data for the current file cannot be displayed graphically. Either they do not
match the selected format or they do not contain any tool actions. Another cause for
failure may be that the format identification is switched off or that an incorrect data
format has been adjusted.
Tool not yet defined
A tool is needed which has not yet been programmed in the tool management
system. The appropriate parameters must always be defined prior to using tools.
No tool file found
No tool file can be found. WinPC-NC therefore continues to work with default
values.
Machine is at limit switch
When both limit switches on an axis are defined, WinPC-NC is unable to tell which
switch has been reached. Please move the axes in question back from the limit
switch manually and then restart reference travel.
Service code required
The axis controller can no longer be controlled and requires a service code before
continuing work. Please contact the supplier.
Command rejected by controller
An internal error has occurred in WinPC-NC during communication with the
realtime module. Please report this error to the program authors, providing as many
details as possible.
Maschine not ready
The machine has not been switched on or there is a fault. The NOT READY input
on the axis controller signals this condition.