BEDIENUNGSANLEITUNG OPERATING INSTRUCTIONS Version 01/14 GSM-Fernschalt-/Alarmmodul „GX107“ Seite 2 - 49 GSM Remote Control / Alarm Module „GX107“ Page 50 - 97 Best.-Nr. / Item No.
Inhaltsverzeichnis Seite 1. Einführung .................................................................................................................... 4 2. Bestimmungsgemäße Verwendung ............................................................................ 5 3. Lieferumfang ................................................................................................................ 6 4. Symbol-Erklärung .................................................................................
Seite 13. System-Befehle .......................................................................................................... 35 13.1 Alarm-Timer ................................................................................................................ 35 13.2 GSM-Zellen-Informationen ........................................................................................ 36 13.3 Hysterese-Funktion (ab Firmware 1.11d) ................................................................. 37 14.
1. Einführung Sehr geehrte Kundin, sehr geehrter Kunde, wir bedanken uns für den Kauf dieses Produkts. Dieses Produkt entspricht den gesetzlichen, nationalen und europäischen Anforderungen. Um diesen Zustand zu erhalten und einen gefahrlosen Betrieb sicherzustellen, müssen Sie als Anwender diese Bedienungsanleitung beachten! Lesen Sie sich vor Inbetriebnahme des Produkts die komplette Bedienungsanleitung durch, beachten Sie alle Bedienungs- und Sicherheitshinweise.
2. Bestimmungsgemäße Verwendung Das GSM-Fernschalt-/Alarmmodul verfügt über 2 Schaltausgänge, welche wahlweise über SMS oder Anruf (INCALL) geschaltet werden können. Ein analoger Eingang (ADC) kann sowohl eine externe Spannung messen als auch zur Verwendung eines optionalen Temperatur-Sensors (Conrad Best.-Nr. 198896) umkonfiguriert werden. Der Optokoppler-Eingang (IN1) dient zur Überwachung von Schaltsignalen. Als Zubehör kann ein GPS-Empfänger erworben werden (Conrad-Best.-Nr.
3. Lieferumfang • GSM-Fernschalt-/Alarmmodul für „GX107“ • Kabeldurchführungen und Verschlussstopfen • Bedienungsanleitung 4. Symbol-Erklärung Das Symbol mit dem Blitz im Dreieck wird verwendet, wenn Gefahr für Ihre Gesundheit besteht, z.B. durch elektrischen Schlag. Das Symbol mit dem Ausrufezeichen im Dreieck weist auf wichtige Hinweise in dieser Bedienungsanleitung hin, die unbedingt zu beachten sind.
5. Sicherheitshinweise Bei Schäden die durch Nichtbeachten dieser Bedienungsanleitung verursacht werden, erlischt die Gewährleistung/Garantie! Für Folgeschäden übernehmen wir keine Haftung! Bei Sach- oder Personenschäden, die durch unsachgemäße Handhabung oder Nichtbeachten der Sicherheitshinweise verursacht werden, übernehmen wir keine Haftung! In solchen Fällen erlischt die Gewährleistung/Garantie! • Dieses Modul hat das Werk in sicherheitstechnisch einwandfreiem Zustand verlassen.
Es ist anzunehmen, dass ein gefahrloser Betrieb nicht mehr möglich ist, wenn: - das Gerät sichtbare Beschädigungen aufweist - das Gerät nicht mehr arbeitet - das Gerät längere Zeit unter ungünstigen Verhältnissen gelagert wurde - schwere Transportbeanspruchungen aufgetreten sind • Schalten Sie das Gerät niemals gleich dann ein, wenn dieses von einem kalten in einen warmen Raum gebracht wurde. Das dabei entstandene Kondenswasser kann unter Umständen Ihr Gerät zerstören.
6. Allgemeine Akkuhinweise • Der Akku gehört nicht in Kinderhände. • Ein ausgelaufener oder beschädigter Akku kann bei Berührung mit der Haut Verätzungen verursachen, benutzen Sie deshalb in diesem Fall geeignete Schutzhandschuhe. • Der Akku darf niemals kurzgeschlossen oder ins Feuer geworfen werden.
8. Anschlüsse und LEDs Die Beschreibung der Anschlüsse und LEDs finden Sie auf der nächsten Seite.
1 LED (rot) = Akku Laden 2 LED (grün) = Akku voll 3 LED (rot) = Fehler und Info-Anzeige leuchtet: falscher PIN blinkt 3x kurz: Factory-Reset (in Verbindung mit S1) blinkt 1x während Betrieb: SMS empfangen 4 LED (grün) = GSM-Status blinkt: „GX107“ an Netz angemeldet leuchtet: Netzsuche, keine Netzverbindung 5 LED (blau) = GPS-Status blinkt: aktuelle GPS-Position bestimmt leuchtet: GPS aktiviert, Position nicht bestimmt (Empfängerposition?) 6 LED (orange) OUT2 (Transistor) 7 LED (orange) OUT1 (Re
Eingänge Es gibt einen Eingang für die Betriebsspannung (15), einen Eingang für den Anschluss eines Akkus (LiIon, 14), einen analogen Eingang (16) und einen Optokoppler (17). Beachten Sie die maximale Eingangsspannung von 2,8 V an dem ADC und die maximale Eingangsspannung von 32 V/DC an dem Optokopplereingang und der Betriebsspannung! Ausgänge Jeder Ausgang besitzt eine eigene LED, welche den aktuellen Status anzeigt. Der erste Ausgang (19) ist bereits an ein Relais angeschlossen.
Akku Der Akku befindet sich im Gehäusedeckel und wird mit einem Metall-Bügel befestigt. Zur Verbindung mit dem „GX107“ dient ein dreiadriges Kabel mit einem verpolungssicheren Stecker. Wenden Sie beim Anschluss keine Gewalt an! Bevor Sie das Gehäuse schließen, achten Sie darauf, dass das Akkukabel an die Buchse (14) auf der Vorderseite der Platine angeschlossen ist. Ein Anschlussfehler wird durch das Leuchten der beiden LEDs (1 & 2) nach dem Anschluss der Betriebspannung (15) signalisiert.
9. Inbetriebnahme - erste Schritte Die Inbetriebnahme darf grundsätzlich nur erfolgen, wenn das Modul berührungssicher in ein Gehäuse eingebaut ist. Es ist vor der Inbetriebnahme einer Baugruppe generell zu prüfen, ob sie grundsätzlich für den Anwendungsfall, für den sie verwendet werden soll, geeignet ist! Im Zweifelsfalle sind unbedingt Rückfragen bei Fachleuten, Sachverständigen oder den Herstellern der verwendeten Baugruppen notwendig! Betriebsspannung Öffnen Sie das Gehäuse, d.h.
Nachdem Sie den PIN-Code Ihrer SIM-Karte geändert haben, können Sie diese aus Ihrem Mobiltelefon entfernen und in das „GX107“ einlegen. Der SIM-Einschub befindet sich auf der Vorderseite der Platine des „GX107“ unter dem Gehäusedeckel. Nochmals zur Verdeutlichung - gehen Sie in folgenden Schritten vor: SIM-Karte mit PIN 1513 1. Legen Sie die für das „GX107“ vorgesehene SIM-Karte in Ihr Mobiltelefon ein. 2. Ändern Sie gemäß der Bedienungsanleitung Ihres Mobiltelefons den PINCode auf 1513 ab. 3.
Einschalten Nach dem Einlegen der SIM-Karte schaltet sich das „GX107“ automatisch ein. Das signalisiert die grüne LED (Status GSM (4)): Zuerst leuchtet die LED durchgehend (Netzsuche) und nach ein paar Sekunden sollte die LED mit dem Blinken beginnen (Netz gefunden, „GX107“ betriebsbereit). Sollte die grüne StatusLED nicht anfangen zu blinken, so existiert ein Fehler bei der Verbindung zum GSM-Anbieter.
10. Einführung Befehlformat Bevor Sie das „GX107“ einsetzen können, müssen Sie es zunächst konfigurieren. Die Konfiguration erfolgt mittels einfacher SMS-Befehle, die Sie von ihrem Mobiltelefon aus an das „GX107“ (an die Rufnummer der SIM-Karte des „GX107“) senden. Diese Methode ermöglicht es, Ihr „GX107“ von jedem beliebigen Standort aus zu aktivieren, deaktivieren oder die Einstellungen zu ändern. Die Textnachrichten (SMS) zur Programmierung des „GX107“ sind nach folgendem Schema aufgebaut: <1. Wort> <2.
Beispiele: Ausgang 1 einschalten (vorausgesetzt, die PIN des „GX107“ ist 1513): SET OUT1 #1513 Sprache (Deutsch) setzen: SET LANGUAGE DE #1513 Hinweis zum RESET-Befehl: Sollten Sie eine Funktion ausschalten wollen, oder Sie aufgrund eines Fehlers zurücksetzen, dann senden Sie einen RESET-SMS-Befehl mit dem entsprechenden Funktionswort (2.
11. Allgemeine Befehle In den folgenden Beispielen wird vorausgesetzt, dass die PIN der im „GX107“ eingesetzten SIM-Karte „1513“ lautet. Entsprechend der von Ihnen eingestellten PIN ist dafür natürlich die „1513“ durch Ihre PIN zu ersetzen. 11.1 Abfrage des Status Sie haben die Möglichkeit, den Status des „GX107“ und die Parameter zu prüfen. Sie bekommen eine SMS, die Sie über den Batteriezustand, den GSM-Empfang, Aus-/Eingangstatus, Spannung usw. informiert. Befehl: STATUS #1513 Antwort: GX107 1.
11.2 Alarmmodus Das „GX107“ besitzt diverse Auslösemöglichkeiten, um den Benutzer durch SMS und E-Mail zu alarmieren. Mit dem folgenden Befehl steuern Sie zentral die Alarm-Funktionen. Erst mit „ENABLE“ erlauben Sie dem „GX107“ selbstständig bei eingestellten und erkannten Ereignissen eine SMS und Email an die gespeicherten Nummern/Adressen zu senden. Mit „DISABLE“ generiert das „GX107“ nur noch eine SMS an die Telefonnummer, welche zuvor eine SMS mit der korrekten PIN gesendet hat.
11.3 Einspeichern von Telefonnummern In das „GX107“ kann man bis zu 6 Telefonnummern programmieren. Im Alarmfall wird eine Benachrichtigungs-SMS an jede dieser Telefonnummern geschickt. Zudem werden nur diese Telefonnummern für die INCALL-Funktion akzeptiert. Sollte sich die gleiche Telefonnummer mehrmals in der Liste befinden, erhält diese entsprechend oft die gleiche SMS-Nachricht. Das „GX107“ kann grundsätzlich nur Telefonnummern im internationalen Format verarbeiten.
Telefonbereiche (Betrifft nur Funktion INCALL): Ab der Firmware Version 1.11d (zu sehen in jeder Antwort-SMS) können Sie Telefon-Bereiche definieren, die für die Funktion „INCALL“ erlaubt werden. Beispiel: Sie wollen die folgenden Nummern für den INCALL freigeben: +491555512345 +491555523456 +491555534567 dann programmieren Sie z.B. die folgende Telefonnummer: +4915555***** Die * sind Platzhalter für beliebige Zahlen. Bitte achten Sie darauf, dass entsprechend genügende Platzhalter (*) eingefügt werden.
11.4 Änderung des Gerätenamens Falls mehrere „GX107“-Geräte gleichzeitig betrieben werden, ist es empfehlenswert jedem Gerät einen eigenen Namen zu geben. Auf diese Weise kann man Alarmmeldungen dem richtigen Gerät zuordnen. Um Namensänderungen an Ihrem „GX107“-Gerät vorzunehmen, senden Sie folgenden SMSBefehl. SET NAME #1513 Beispiel: Umbenennung des „GX107“ in „NEWNAME“ SET NAME NEWNAME #1513 Sie erhalten folgende Bestätigungs-SMS: NEWNAME 1.xx --------... ...
11.6 Änderung SIM-PIN Änderung des PIN-Codes: Sie können Ihr „GX107“ vor unbefugtem Zugriff effizient schützen, indem Sie einen individuellen PIN-Code für die SIM-Karte erstellen, welcher künftig an jeden SMS-Befehl angehängt werden muss.
11.7 Email Sie können im Alarmfall ebenfalls per Email benachrichtigt werden. Um eine Email-Adresse abzuspeichern, gehen Sie wie folgt vor: SET EMAIL #Thema# #1513 Beispiel: SET EMAIL hans.muster@provider.net#Alarm# 5555 #1513 Die maximale Länge der Email-Adresse und #Thema# beträgt zusammen 35 Zeichen. Die Service-Center-Nummer erfahren Sie von Ihrem Provider.
12. Schnittstellen-Befehle Dies ist ein autonom arbeitendes Alarm-Meldegerät. Durch falsche Einstellungen bzw. Anschlüsse kann es zu ungewünschten SMSAussendungen kommen! Tragen Sie auf keinen Fall die Telefonnummer von der SIM-Karte ein, die im Modul eingesetzt wird! Tragen Sie auch keine Telefonnummer anderer „GX107“ oder Meldegeräte ein. 12.1 Ausgänge ein-/ausschalten (OUT1, OUT2) Dies sind die zwei Ausgänge OUT1 und OUT2, die durch Senden einer SMS an das Modul einund ausgeschaltet werden können.
12.2 Optokoppler-Eingang (IN1) Der Eingang IN1 ist ein Optokoppler und wird für z.B. Rauchmelder oder Einbruchsmelder (Stromschleifen, die unterbrochen werden) verwendet. Am Eingang kann eine Spannung von 0 bis 32 V potentialfrei von der restlichen Schaltung angeschlossen werden. Beachten Sie hierbei die Polarität (Plus/+ und Minus/-)! Ohne externe Spannung (also offen) oder mit Spannung niedriger als 2 V wird dieser Eingang (IN1) als Low-Pegel erkannt.
Neue Funktion ab Firmware 1.11d: Über einen optionalen 2. Parameter kann man einstellen, wie lange ein Signal ununterbrochen anliegen muss, bevor ein Alarm ausgelöst wird. SET IN1
12.3 Analoger Eingang (ADC) Dies ist ein analoger ADC-Eingang. Dieser Eingang kann eine Spannung von 0 V bis 2,8 V messen. Er kann auch für die Temperatursensoren verwendet werden. Bei Über- oder Unterschreiten eines einstellbaren Grenzwertes (in mV oder °C) kann das Modul automatisch eine Alarmmeldung senden. Bitte beachten Sie, dass es bei der maximalen Spannung von 2,8 V zu Messfehlern kommen kann. Die Eingabe der Grenzwerte geschieht in mV, so muss z.B.
Einstellungen des ADC prüfen Um die gewünschten Einstellungen des ADC zu prüfen, verwenden Sie den Befehl: TEST ADC #1513 Um den analogen Eingang für den Temperaturfühler zu verwenden, benutzen Sie den Befehl: SET ADCMODE TEMP #1513 Danach wird der Temperaturfühler (z.B. Conrad Best.-Nr. 198896) am analogen Eingang entsprechend ausgewertet.
Bei einer Temperatur kleiner als -5,0 °C oder größer als +25,0 °C löst das „GX107“ Alarm aus. Der Bereich der Grenzeneinstellung ist von -400 bis +1250 einstellbar. Wenn als „Temp1“ = +1250 eingestellt wird, wird die obere Grenze ausgeschaltet. Wenn als „Temp2“ = -400 eingestellt wird, wird die untere Grenze ausgeschaltet. Die Angabe der Vorzeichen „+“ und „-“ vor den Zahlen ist zwingend erforderlich. Ohne das entsprechende Vorzeichen wird ein Fehler ausgegeben.
12.4 Anruf (INCALL) Die „INCALL“-Funktion kann mit jedem Ausgang („OUT1“=Relais, „OUT2“= Transistor) verbunden werden. Diese Funktion kann in zwei Modi eingesetzt werden: Modus „Toggeln“: Der Ausgang wird bei Anruf umgeschaltet Modus „Time“: Ausgang wird für eine einstellbare Zeit eingeschaltet Nur die zuvor mit dem Befehl SET TEL gespeicherten Telefonnummern können diese Funktion verwenden. Sie rufen einfach das „GX107“ an und lassen es sicherheitshalber ein paar Mal klingeln.
Einstellungen prüfen Um die gewünschten Einstellungen zu prüfen, verwenden Sie den Befehl: TEST INCALL #1513 Bei korrekter Erkennung des Anrufers und Ausführung der Aktion (schalten) wird dieser Anruf abgewiesen. Dies dient zur Bestätigung.
12.5 Betriebsspannungsüberwachung Die richtige Spannung der Energieversorgung für das „GX107“ ist von 5 V bis 32 V. Das „GX107“ kann die Spannung der Energieversorgung kontrollieren und Sie informieren (d.h. eine Alarm-SMS senden), wenn die Spannung zu niedrig ist oder es keine Spannung gibt. Diese Funktion wird beispielsweise benötigt, wenn das „GX107“ von der Autobatterie versorgt wird.
13. System-Befehle Mit den folgenden Befehlen können Sie wichtige Schutzfunktionen des „GX107“ verändern. Falls Sie die Default-Einstellungen verändern, akzeptieren Sie das daraus resultierende, geänderte Verhalten des „GX107“. 13.1 Alarm-Timer Im Alarmfall sendet das „GX107“ eine Alarmmitteilung. Weitere Mitteilungen des gleichen Typs werden nur versendet, wenn die entsprechende Alarmsituation für eine bestimmte Zeitspanne (Werkseinstellung: 5 Minuten) verlassen wurde.
Beispiel: Der Schalteingang wurde so konfiguriert, dass bei HIGH ein Alarm ausgelöst wird. Der IdleCountdown startet ab dem Zeitpunkt, wo IN1 den LOW Zustand erreicht hat. Sollte innerhalb der IDLE-Time der Alarmzustand von IN1 wieder erreicht werden (HIGH), wird der Countdown zurück gesetzt, jedoch kein Alarm ausgelöst (Idle-Time wurde nicht abgewartet). Erst wenn IN1 für mindestens die eingestellte IDLE-Time den LOW Zustand ununterbrochen eingehalten hat, kann IN1 wieder eine Alarm-SMS auslösen.
13.3 Hysterese-Funktion (ab Firmware 1.11d) Die Default- Einstellungen wurden bereits so gewählt, dass sie für die meisten Anwendungsfälle geeignet sind. Eine Änderung ist nur in Sonderfällen nötig. Um ungewollte Alarmierungen zu vermeiden, wurde die neue Funktion „Hysterese“ programmiert. Bei einer Hysterese verändert sich die Alarmschwelle nach dem Überschreiten um den Hysterese-Wert. Dadurch muss der Analogwert sich zuerst weiter in den erlaubten Bereich begeben, bevor der Alarmzustand aufhört.
14. GPS-Anwendung und Befehle Das „GX107“ kann mit einem externen GPS-Modul ausgestattet werden (Conrad Best.-Nr. 199310). Das GPS-Modul ermöglicht eine Positionsbestimmung des Gerätes auf der ganzen Welt via Satellit (Sichtkontakt zu einer genügenden Anzahl an GPS-Satelliten vorausgesetzt!). Das „GX107“ mit GPS-Modul kann Ihnen den Standort per SMS zuschicken. Sie können den Standort des Gerätes von jedem beliebigen Ort mit Hilfe Ihres Handys prüfen. Den genauen Standort kann dann in z.B.
Wenn Sie ein Mobiltelefon mit Verbindung zum Internet haben, können Sie folgenden Befehl verwenden: TEST GPSMAP #1513 Muster Rückantwort: GX107 1.XX Time: 12:22:34 siehe Karte: Name des Geräts, Software-Version Zeit: UTC der letzten Position Link zur Landkarte Nachdem Sie den Link klicken, sieht man auf dem Display Ihres Mobiltelefons, wo sich das „GX107“ befindet (in der Mitte der Landkarte).
Zoom und Mapanbieter wechseln (seit Firmware 1.10m): Sie können neben dem Zoomfaktor des Links auch den Anbieter wechseln. Dies erreichen Sie mit dem folgenden Parameter und Werten: SET GPSMAP #1513 Der Parameter NR hat folgende Bedeutung: 0 OSM Karte, Standard Zoom (Default) 1-6 OSM Karte, 1-6 unterschiedliche Zoomwerte 100 GoogleMaps mit aktualisiertem Link-Format 101-106 GoogleMaps mit unterschiedlichen Zoomwerten Als Antwort bekommen Sie eine SMS mit dem neuen Link.
14.3 Automatische Positionsübermittlung Manchmal in Alarmsituationen benötigt man die Information über den Standort mehrmals in kurzer Zeit (beim Verfolgen des Gerätes). Man kann in solchem Fall folgenden Befehl schicken: TEST GPS #1513 oder TEST GPSMAP #1513 Zeit = Zeit in Minuten zwischen den Meldungen (1-249) 250: 30 Sekunden 251: 15 Sekunden Menge: Max.
14.4 Energie sparen Um Energie zu sparen und so die Akkulaufzeit zu erhöhen, wird im Akkubetrieb (ohne externe Betriebsspannung) der GPS-Empfänger die meiste Zeit ausgeschaltet. Falls das „GX107“ seine Position ändert (Änderung der GSM-Funkzelle) oder das „GX107“ einen GPS Befehl bekommt, wird der aktuelle GPS-Standort sofort aktualisiert. Andernfalls wird der GPS-Empfänger nach einer einstellbaren Zeit für ein paar Minuten reaktiviert.
14.5 GPS-Zone Das „GX107“ mit angeschlossenem GPS-Modul kann zur Zonen-Überwachung verwendet werden. Nach der Programmierung der zugelassenen Zone(n) (max. 10) und nach der Aktivierung des Alarmmodus („ENABLE“) wird bei jeder Überschreitung der zugelassenen Zone(n) eine Alarmmeldung mit der aktuellen GPS-Koordinate an alle gespeicherten Telefonnummern und Email geschickt. Anmerkung: Die Karte ist dem OpenStreetMap-Projekt entnommen.
Format der Dateneingabe: Die Koordinaten werden in Grad mit 6 Nachkommastellen benötigt. Dies ist das gleiche Format, dass bei GoogleMaps nach einem Rechtsklick-„Was ist hier?“ erscheint. Breitengrad – gg.ggggggN (Grad) z.B.: 49° 59.5058’ N -> 49.991763N Längengrad – ggg.ggggggE (Grad) z.B. 11° 57.0399’ E -> 011.950665E Die GPS-Koordinaten werden beim „GX107“ in Grad mit 6 Nachkommastellen angegeben.
Löschen aller abgespeicherten Zonen Zum Löschen aller abgespeicherten Zonen dient der folgende Befehl: RESET GPSZONE ALL #1513 Löschen einer einzelnen Zone Zum Löschen einer einzelnen Zone dient der folgende Befehl: RESET GPSZONE #1513 Nach dem Löschen rücken alle verbleibenden Zonen entsprechend vor. Wenn zum Beispiel Zonen 1-3 programmiert sind und Zone 2 gelöscht wird, so befindet sich danach Zone 3 nun auf dem 2. Speicherplatz und wird daher als Zone 2 angezeigt.
Sie können mehrere Zonen zu einem Korridor zusammenfügen. Die Grenzen der Zonen verlaufen entlang der angegebenen Längen- und Breitengrade. Diagonale Zonen können nicht angegeben werden. Die Zonen müssen dabei einander überlappen, sofern diese zu einem Korridor zusammengehören.
15. Zurücksetzen auf Werkseinstellungen Sie können das „GX107“ auf die Werkseinstellung zurücksetzen. Hierzu halten Sie alle zwei Tasten (RESET und S1) gleichzeitig gedrückt. Lassen Sie die Taste RESET los und die Taste S1 halten Sie noch 10 Sekunden lang gedrückt. Sobald die rote LED blinkt, sind alle Geräteeinstellungen zurückgesetzt.
17. Entsorgung 17.1 Produkt Entsorgen Sie das Produkt am Ende seiner Lebensdauer gemäß den geltenden gesetzlichen Vorschriften. 17.2 Batterien und Akkus Sie als Endverbraucher sind gesetzlich (Batterieverordnung) zur Rückgabe aller gebrauchten Batterien und Akkus verpflichtet; eine Entsorgung über den Hausmüll ist untersagt! Schadstoffhaltige Batterien/Akkus sind mit nebenstehendem Symbole gekennzeichnet, das auf das Verbot der Entsorgung über den Hausmüll hinweisen.
19. Technische Daten Betriebsspannung ................................ 5 bis 32 V/DC, min. 700 mA Modul .................................................... Wavecom Q2400 Frequenzbänder .................................. EGSM900 (880 bis 960 MHz) DCS1800 (1710 bis 1880 MHz) GSM-Klassen ....................................... Klasse 4 (2 Watt) bei EGSM900 Klasse 1 (1 Watt) bei DCS1800 SIM ....................................................... 3 V SIM-Karte Externe GSM-Antenne ........................
Table of Contents Page 1. Introduction ................................................................................................................. 52 2. Intended Use .............................................................................................................. 53 3. Scope of Delivery ....................................................................................................... 54 4. Explanation of Symbols .............................................................
Page 13. System Commands .................................................................................................... 83 13.1 Alarm Timer ................................................................................................................ 83 13.2 GSM Cell Information ................................................................................................. 84 13.3 Hysteresis Function (Firmware 1.11d and Newer) ................................................... 85 14.
1. Introduction Dear Customer, Thank you for purchasing this product. This product complies with the statutory national and European requirements. To maintain this status and to ensure safe operation, you as the user must observe these operating instructions! Read the complete operating instructions before taking the product into operation; observe all operating notes and safety information. All company names and product names are trademarks of their respective owners. All rights reserved.
2. Intended Use The GSM remote control/alarm module has 2 switching outputs that can be switched either via text message or via call (INCALL). An analogue input (ADC) can measure both an external voltage and be reconfigured to use an optional temperature sensor (Conrad item no. 198896). The optocoupler input (IN1) is used to supervise switching signals. Accessories available include a GPS receiver (Conrad item no.
3. Scope of Delivery • GSM remote control / alarm module for “GX 107” • Cable feedthroughs and closing plugs • Operating instructions 4. Explanation of Symbols The symbol with a lightning in a triangle is used where there is a health hazard, e.g. from electric shock. An exclamation mark in a triangle indicates important notes in these operating instructions that must be strictly observed. 54 The “hand” symbol indicates special information and advice on operation.
5. Safety Information The guarantee/warranty will expire if damage is incurred resulting from noncompliance with the operating instructions! We do not assume any liability for consequential damage! We do not assume any liability for damage to property or personal injury caused by improper use or the failure to observe the safety instructions! In such cases the guarantee/warranty will expire! • This module left the factory in perfect condition in terms of safety engineering.
It can be assumed that safe operation is no longer possible if: - the device shows visible damage - the device no longer functions - the device was stored under unfavourable conditions for an extended period of time - if it was subjected to heavy stress during transport • Do not switch on the device immediately after it was taken from a cold to a warm environment. The condensation that forms might destroy your device. Allow the device to reach room temperature before switching it on.
6. General Notes on Rechargeable Batteries • Keep the rechargeable battery out of reach of children. • Leaking or damaged batteries/rechargeable batteries can cause chemical burns to skin when touched without the use of adequate protective gloves. • The rechargeable battery must never be short-circuited or thrown into fire.
8. Connections and LEDs For the connection and LED descriptions, see the next page.
1 LED (red) = Charge battery 2 LED (green) = Battery charged 3 LED (red) = Error and information display Lit: Wrong PIN Flashes briefly 3x: Factory reset (in connection with S1) Flashes 1x in operation: Text message received 4 LED (green) = GSM status Flashes: “GX107” logged on to the network Lit: Network search, no network connection 5 LED (blue) = GPS status Flashes: Current GPS position determined Lit: GPS activated, position not determined (receiver position?) 6 LED (orange) OUT2 (transistor)
Inputs There is an input for operating voltage (15), an input for connection of a rechargeable battery (LiIon, 14), an analogue input (16) and an optocoupler (17). Observe the maximum input voltage of 2.8 V at the ADC and a maximum input voltage of 32 V/DC at the optocoupler input and operating voltage! Outputs Each output has its own LED to display the current status. The first output (19) is already connected to a relay. Observe the connection data of the relay (5 A at 30V/DC or 8 A at 250 V/AC).
Rechargeable Battery The rechargeable battery is located in the casing lid and is attached with a metal bracket. A three-wire cable with plug protected against polarity reversal is used for connection with the “GX107”. Do not use any force for connection! Before closing the casing, ensure that the battery cable is connected to the socket (14) on the front of the PCB. A connection error is signalled by the two LEDs (1 & 2) being lit after connection of the operating voltage (15).
9. Commissioning - First Steps The module may only be commissioned after it has been installed contact-free in a casing. Prior to commissioning the module group, check whether it is suited for the intended application! In case of doubt, you must contact an expert or the manufacturer! Operating voltage Open the casing, i.e. turn out the 4 screws and remove the casing lid. Direct voltage of 5 to 32 V/DC is required at the input clamps (15). Observe correct polarity (plus/+ and minus/-).
For clarification - proceed as follows: SIM card with PIN 1513 1. Insert the SIM card intended for the “GX107” in your mobile phone. 2. Change the PIN code to 1513 according to your mobile phone’s operating instructions. 3. Remove the SIM card with the changed PIN code from your mobile phone. 4. Insert the SIM card with the changed PIN code into the “GX107”. The SIM insert is on the front of the “GX107”’s PCB, below the casing lid.
Switching on the Devices Once the SIM card is inserted, the “GX107” switches on automatically. This is signalled by the green LED (status GSM (4)): First, the LED remains lit (network search); after a few seconds, the LED should start flashing (network found, “GX107” ready for operation). If the green status LED does not start to flash, there is an error in the connection with the GSM provider.
10. Introduction Command Format Before you can use the “GX107”, you have to configure it. Configuration is performed by simple text message commands you send to the “GX107” (the phone number of the SIM card in the “GX107”) from your mobile phone. This method makes it possible to activate, deactivate or change the settings of your “GX107” from anywhere. The text messages to programme the “GX107” have the following structure: <1.
Examples: Switch on output 1 (if the PIN of the “GX107” is 1513): SET OUT1 #1513 Set language (German): SET LANGUAGE DE #1513 Note on the RESET command: If you want to switch off a function or reset it due to an error, send a RESET text message command with the matching function word (2nd word): RESET #PIN This command works universally for all functions/text message commands! Example: Switching off output 1: RESET OUT1 #1513 More information: • Capitalisation is not relevant; you may use capital
11. General Commands In the following examples, it is assumed that the PIN of the SIM card in the “GX107” is “1513”. According to the PIN set by you, you have to replace the “1513” by your own PIN, of course. 11.1 Status Request You have the option of checking the status of the “GX107” and the parameters. You will receive a text message informing you of battery condition, GSM reception, out-/input status, voltage, etc. Command: STATUS #1513 Answer: GX107 1.
11.2 Alarm Mode The “GX107” has several trigger options to alarm the user by text message and email. The following command permits central control of the alarm functions. Only “ENABLE” will permit the “GX107” to independently send a text message and email to the numbers/addresses saved for set and recognised events. With “DISABLE”, the “GX107” will only generate a text message to the phone number that previously sent a text message with the correct PIN.
11.3 Saving Phone Numbers Up to 6 phone numbers can be programmed into the “GX107”. In case of alarm, a notification text message is sent to each of these phone numbers. Additionally, only these phone numbers are accepted for the INCALL function. If the same number is in the list several times, it will receive the same text message as many times. The “GX107” generally can only process phone numbers in the international format.
Phone areas (only affects function INCALL): As of firmware version 1.11d (indicated in every answering text message), you can defined phone areas permitted for the “INCALL” function. Example: If you want to release the following numbers for INCALL: +491555512345 +491555523456 +491555534567 you can programme, e.g., the following phone number: +4915555***** The * are placeholders for any numbers. Ensure that you have entered enough placeholders (*).
11.4 Changing the Device Name If several “GX107” devices are operated at the same time, it is recommended to assign a different name to each device. This makes it possible to assign alarm messages to the correct device. To change the name at your “GX107” device, send the following text message command. SET NAME #1513 Example: Renaming “GX107” to “NEWNAME” SET NAME NEWNAME #1513 You will receive the following confirmation text message: NEWNAME 1.xx --------... ...
11.6 Changing the SIM-PIN Changing the PIN code: You may efficiently protect your “GX107” from unauthorised access by generating an individual PIN code for the SIM card that must be appended to every text message command in future.
11.7 Email In case of alarm, you may also be reported by email. To store an email address, proceed as follows: SET EMAIL #Subject# #1513 Example: SET EMAIL hans.muster@provider.net#Alarm# 5555 #1513 The maximum length of the email address and #subject# together is 35 characters. Contact your provider about the service centre number. A text message is set to the service centre number, which will pass on the message as an email to the address.
12. Interface Commands This is an autonomously working alarm messaging device. Wrong settings or connections may cause undesired text messages to be sent! Never enter the phone number that belongs to the SIM card that is inserted in the module! Also never enter any phone numbers from any other “GX107” or reporting devices. 12.1 Switching Outputs On/Off (OUT1, OUT2) These are the two outputs OUT1 and OUT2 that can be switched on and off by sending a text message to the module.
12.2 Optocoupler Input (IN1) The input IN1 is an optocoupler and used, e.g., for smoke detectors or burglary alarms (current loops that are interrupted). A voltage of 0 to 32 V can be connected to the input potential-free against the remaining circuit. Observe correct polarity (plus/+ and minus/-)! Without any external voltage (i.e. open) or with a voltage of less than 2 V, this input (IN1) is recognised as a low level. If an external voltage in excess of 3.
New Function as of Firmware 1.11d: An optional second parameter can be used to set how long a signal must be pending without interruption before an alarm is triggered. SET IN1 #1513 The parameter indicates the time in seconds before an alarm is triggered. The value range is at: 0 = Off (default) or 1 to 90 (in seconds) Observe that not using a 2nd parameter will not change the time.
12.3 Analogue Input (ADC) This is an analogue ADC input. This input can measure a voltage of 0 V to 2.8 V. It can also be used for the temperature sensors. When an adjustable threshold value (in mV or °C) is exceeded or undercut, the module can automatically send an alarm message. Please observe that the maximum voltage of 2.8 V may lead to measuring errors. Threshold values are input in mV; e.g., a threshold voltage of 1.2 V requires sending a value of 1200 to the “GX107”. This function is intended, e.g.
Checking the ADC settings To verify the desired settings of the ADC, use the command: TEST ADC #1513 To use the analogue input for the temperature sensor, use the command: SET ADCMODE TEMP #1513 Then the temperature sensor (e.g. Conrad item no. 198896) is assessed accordingly at the analogue input.
For a temperature of less than -5.0 °C or more than +25.0 °C, the “GX107” will trigger an alarm. The threshold setting area can be set from -400 to +1250. If “Temp1” is set to = +1250, the top threshold is deactivated. If “Temp2” is set to = -400, the lower threshold is deactivated. Indication of prefixes “+” and “-” before the figures is mandatory. Without the corresponding prefix, and error will be output. An error will also be output if the value of “Temp2” is larger than “Temp1”.
12.4 Call (INCALL) The “INCALL” function can be connected to any output (“OUT1”=relay, “OUT2”= transistor). This function can be used in two modes: Mode “Toggle”: The output is switched at call Mode “Time”: Output is activated for an adjustable time Only the phone numbers previously stored with the command SET TEL may use this function. Just call the “GX107” and let it ring a few times to be safe.
Checking settings To verify the desired settings, use the command: TEST INCALL #1513 If the caller is recognised correctly and the action (switching) is performed correctly, this call is rejected. This serves as confirmation. If the “GX107” does not reject the call, either the phone number was not recognised correctly, or does not match any number if the “Set Tel” list (did you forget the international format?), the function is not activated and/or an error has occurred in performance.
12.5 Operating Voltage Monitoring The correct voltage of the power supply for the “GX107” is between 5 V and 32 V. The “GX107” can verify the voltage of the power supply and inform you (i.e. send an alarm text message) if the voltage is too low or no voltage is present. This function is required, e.g. if the “GX107” is supplied by a car battery. If the car battery is discharged too far or the car’s power supply is manipulated, the “GX107” will automatically send an alarm message.
13. System Commands With the following commands, you can change important protective functions of the “GX107”. If you have the default settings, you thereby accept the resulting changed behaviour of the “GX107”. 13.1 Alarm Timer In case of alarm, the “GX107” will send an alarm message. Further messages of the same type are only sent if the corresponding alarm situation was left for a specified period (factory settings: 5 minutes). This period can be changed.
Example: The switching input was configured to trigger an alarm at HIGH. The idle countdown starts when IN1 has reached the LOW condition. If the alarm condition if IN1 is reached again during the IDLE time (HIGH), the countdown is reset but no alarm is triggered (idle time did not elapse). Only when IN1 retained the LOW condition without interruption for at least the set IDLE time will IN1 be able to trigger an alarm text message again. This does not affect any other alarm like ADC or GPS.
13.3 Hysteresis Function (Firmware 1.11d and Newer) The default settings were already chosen to be suitable for most applications. Changes are only necessary in exceptions. To prevent undesired alarms, the new “hysteresis” function was programmed. Hysteresis will cause the alarm threshold to change after the hysteresis value is exceeded. This requires the analogue value to enter the permitted area further before the alarm condition stops.
14. GPS Application and Commands The “GX107” can be equipped with an external GPS module (Conrad item no. 199310). The GPS module enables determination of position of the device around the world by satellite (sight contact to a sufficient number of GPS satellites required!). The “GX107” with GPS module can send you the site per text message. You can verify the device site from any position with your mobile phone. To precise site can be displayed, e.g. in a route planner. 14.
If your mobile phone has internet connect, you may use the following command: TEST GPSMAP #1513 Sample response: GX107 1.XX Time: 12:22:34 See map: Device name, software version Time: UTC of the last position Link to map After clicking the links, your mobile phone’s display will show you where the “GX107” is located (at the centre of the map).
Changing zoom and map provider (firmware 1.10m and newer): You may change the zoom factor of the link as well as the provider. For this, use the following parameters and values: SET GPSMAP #1513 The parameter NR has the following meaning: 0 OSM map, standard zoom (default) 1-6 OSM map, 1-6 different zoom values 100 GoogleMaps with updated link format 101-106 GoogleMaps with different zoom values Your answer will be a text message with a new link.
14.3 Automatic Position Transmission Sometimes, information on the site is required several time quickly in alarm situations (when following the device). In this case, send the following command: TEST GPS #1513 or TEST GPSMAP #1513 Time = time in minutes between the messages (1-249) 250: 30 seconds 251: 15 seconds Quantity: Max.
14.4 Saving Power To save power and increase the battery runtime, the GPS receiver is deactivated most of the time in battery operation (without external operating voltage). If the “GX107” changes position (change of the GSM radio cell) or the “GX107” receives a GPS command, the current GPS site is updated at once. Otherwise, the GPS receiver is reactivated for a few minutes after a set time.
14.5 GPS Zone The “GX107” with connected GPS module can be used to monitor zones. After pogromming of the permitted zone(s) (max. 10) and after activation of the alarm mode (“ENABLE”), every time the permitted zone(s) are exceeded will cause an alarm message with the current GPS coordinate to be sent to all saved phone numbers and emails. Note: The map is taken from the OpenStreetMap project. If the input voltage is connected, the current site is verified every second.
Data input format: Coordinates are given in degree with 6 fractional digits. This is the same format used by GoogleMaps after right click – ”What is this?”. Latitude – gg.ggggggN (degrees) e.g.: 49° 59.5058’ N -> 49.991763N Longitude – ggg.ggggggE (degrees) e.g. 11° 57.0399’ E -> 011.950665E GPS coordinates are given in degree with 6 fractional digits by the “GX107”. Accordingly, the information can be in the following range: XX.000000° to XX.999999° Missing digits must be filled up with “0”.
Deleting all saved zones The following command deletes all saved zones: RESET GPSZONE ALL #1513 Deleting one zone The following command deletes a single zone: RESET GPSZONE #1513 After deletion, all remaining zones will advance by one. For example, if zones 1-3 are programmed and zone 2 is deleted, zone 3 is now on memory space 2 and is thus displayed as zone 2. Switching zone alarm on and off SET/RESET GPSZONE #1513 You can control the alarm for GPS zones separately.
You may combine several zones to one corridor. The zone thresholds are along the indicated longitudes and latitudes. Diagonal zones cannot be indicated. The zones must overlap if they belong to one corridor.
15. Factory Reset You can reset the “GX107” to factory settings. Keep both buttons (RESET and S1) processed at once. Release the RESET button and keep the S1 button pressed for another 10 seconds. When the red LED flashes, all device settings are reset. Then the entire system programming must be repeated (see chapter “First Steps”) Resetting to factory settings changes the “GX107”’s PIN code to “1513”.
17. Disposal 17.1 Product At the end of its service life, dispose of the product according to the relevant statutory regulations. 17.2 Batteries and Rechargeable Batteries You as the end user are required by law (Battery Ordinance) to return all used batteries/ rechargeable batteries. Disposing of them in the household waste is prohibited! Batteries and rechargeable batteries containing hazardous substances are marked with adjacent symbol to indicate that disposal in the household waste is prohibited.
19. Technical Data Operating voltage ................................ 5 to 32 V/DC, min. 700 mA Module .................................................. Wavecom Q2400 Frequency bands ................................. EGSM900 (880 to 960 MHz) DCS1800 (1710 to 1880 MHz) GSM classes ........................................ class 4 (2 Watt) at EGSM900 class 1 (1 Watt) at DCS1800 SIM ....................................................... 3 V SIM card External GSM aerial ............................
http://www.conrad.com CONRAD IM INTERNET http://www.conrad.com Impressum Diese Bedienungsanleitung ist eine Publikation der Conrad Electronic SE, Klaus-Conrad-Str. 1, D-92240 Hirschau (www.conrad.com). Alle Rechte einschließlich Übersetzung vorbehalten. Reproduktionen jeder Art, z. B. Fotokopie, Mikroverfilmung, oder die Erfassung in elektronischen Datenverarbeitungsanlagen, bedürfen der schriftlichen Genehmigung des Herausgebers. Nachdruck, auch auszugsweise, verboten.