4. Operation overview
The module switches a bistable relay with two switches which are
separate from each other. It is triggered by 12 to 18 Volt direct (d.c.) or
alternating (a.c.) voltage. The relay is switched by an earth contact and
can be switched by any earth compatible output (e.g. by a points
decoder). This enables the module to switch two connected electric
loads in joint action. It is possible to connect e.g. a light signal and the
block section that it controls.
5. Technical specifications
Supply voltage 12 - 18 Volt a.c. or d.c. voltage
Number of switches
Maximum current per switch
2
1 A
Protected to
IP 00
Ambient temperature in use 0 ... +60 °C
Ambient temperature in storage -10 ... +80 °C
Comparative humidity allowed max. 85 %
Dimensions of the PCB approx. 26 x 28 mm
Weight of the assembled approx. 7.5 g
Page 9