User manual

Supported Use Cases 17
Doc.Id. HMSI-27-205
Anybus Wireless Bridge - Ethernet to WLAN
Doc.Rev. 1.30
3.2 Two Wireless Bridges Connected as Ethernet Bridge
- Alternative 2
3.2.1 Overview
This use case describes two Wireless Bridges connected in Ethernet Bridge mode. Multiple Ethernet de-
vices on each side of the module are supported. The Ethernet data is bridged through an UDP tunnel,
and Managed (Infrastructure) mode is used.
3.2.2 Set Up the Use Case
This use case can be set up using the SMART button.
To use the Automatic configuration in Managed mode, the Network Name (SSID) and security param-
eters (Encryption, Authentication, User Name and Key) must be configured manually (using the Web
interface or AT commands), unless intending to use the default values. For more information on the
Web interface, see section “Using the Web Configuration Interface” on page 10.
Alternative 1 - SMART Mode
1. Power on the first module and enter SMART configuration mode 8 (wait for automatic config-
uration).
2. Power on the second module and enter SMART configuration mode 9 (initiate automatic con-
figuration).
3. Wait for the modules to connect and restart.
4. The first module will now have the IP address 192.168.0.98, and the second will have IP address
192.168.0.99. The modules will be operating in Managed mode.