Security Datasheet

Conrad Electronic SE, Klaus-Conrad-Str. 1, D-92240 Hirschau
Item no.: 2619571
Material Safety Data Sheet
4. First Aid Measured
Emergency and First Aid Procedures
Contact with internal components if battery is opened/broken.
1. Inhalation
Remove to fresh air and provide medical oxygen/CPR if needed. Obtain medical attention.
2. Eyes
Immediately flush with water for at least 15 minutes, hold eyelids open. Obtain medical attention.
3. Skin
Flush contacted area with large amounts of water for at least 15 minutes. Remove contaminated clothing and obtain medical
attention if necessary.
4. Ingestion
Do not induce vomiting. If conscious drink large amounts of water/milk. Obtain medical attention. Never give anything by mouth
to an unconscious person.
5. Firefighting Measures
Flash Point
Not Applicable
Flammable Limits in Air % by Volume
Not Applicable
Extinguishing Media
Class ABC, CO2, Halon
Auto-Ignition
675°F (polypropylene)
Special Fire Fighting Procedures
Temperature Lead/acid batteries do not burn, or burn with difficulty. Do not use water on fires where molten metal is present.
Extinguish fire with agent suitable for surrounding combustible materials. Cool exterior of battery if exposed to fire to prevent
rupture. The acid mist and vapors generated by heat or fire are corrosive. Use NIOSH approved self-contained breathing
apparatus (SCBA) and full protective equipment operated in positive pressure mode.
Unusual Fire and Explosion Hazards
Sulfuric acid vapors are generated upon overcharge and polypropylene case failure. Use adequate ventilation. Avoid open
flames/sparks/other sources of ignition near battery.
Page 3 of 8