Installation Guide

Connect to Main Line
I
nstall a Slip Compression Tee
Clean off the water service pipe
(
downstream from meter).
Cut out a section of pipe – half the
length of the tee.
Install nuts and washers on each
side of the pipe.
Insert the slip joint tee and tighten
the nuts with a wrench.
Shut-Off Valve – Non-Freezing Area
Install a Gate or Ball valve after the tee and
cover it with an Orbit
®
valve box to protect it
and for easy access to the valve.
Use fittings to install a Gate or Ball valve
on the tee.
Turn on water to flush line of debris.
Cover with an Orbit
®
valve box.
Install a back-flow prevention device (if required). Use local code information to determine:
What type of device is required
How it needs to be installed
Who is authoriz
ed to install it
Installation
Sprinkler System Layout & Installation Guide
14
Water Meter
Water Service Line
Slip Joint Tee To House
Shut–Off Valve
Water Meter
Pipe
Nipple
Water Service Line
Slip Joint Tee
Main Sprinkler Line
System
Shut–Off
Valve
Shut–Off Valve
4
BACKFLOW PREVENTION
Important: Frost Areas or Basement Located Water Meters
Do not use the example abo
v
e if y
ou ar
e connecting t
o a water supply line
that is located in an area with freezing temperatures or a line that has a water
met
er located in the basement.
F
or help in making the pr
oper connections g
o t
o
www
.orbitonline.com for
detailed recommendations or contact your home improvement center.
07WTM003045 53251-01 rE.qxd 3/2/07 2:30 PM Page 14