Data Sheet

MPU-6000/MPU-6050 Product Specification
Document Number: PS-MPU-6000A-00
Revision: 3.4
Release Date: 08/19/2013
20 of 52
6.9 Absolute Maximum Ratings
Stress above those listed as “Absolute Maximum Ratings” may cause permanent damage to the device.
These are stress ratings only and functional operation of the device at these conditions is not implied.
Exposure to the absolute maximum ratings conditions for extended periods may affect device reliability.
Parameter
Rating
Supply Voltage, VDD
-0.5V to +6V
VLOGIC Input Voltage Level (MPU-6050)
-0.5V to VDD + 0.5V
REGOUT
-0.5V to 2V
Input Voltage Level (CLKIN, AUX_DA, AD0, FSYNC, INT,
SCL, SDA)
-0.5V to VDD + 0.5V
CPOUT (2.5V ≤ VDD ≤ 3.6V )
-0.5V to 30V
Acceleration (Any Axis, unpowered)
10,000g for 0.2ms
Operating Temperature Range
-40°C to +105°C
Storage Temperature Range
-40°C to +125°C
Electrostatic Discharge (ESD) Protection
2kV (HBM);
250V (MM)
Latch-up
JEDEC Class II (2),125°C
±100mA