Instructions / Assembly

All Style Industries, LLC
2114 Sunset Vista Avenue Henderson, NV 89052
702-570-5520 or fax 702-754-2597
"mailto:info@stormcollar.com" www.spinflashing.com, or www.stormcollar.com
U.S. Patents 659156181, 664050381 and #7,770,335
Installation Instructions: Steep Slope Roofing
One Retro-Spin Flashing Kit Includes:
1. One (1) All Style Industries Retro-Split® EPDM Storm Collar assembly which includes one wrap-
around skirt, one top plug, and a stainless-steel marine grade band clamp
2. One (1) Retro-Spin® Flashing assembly with tightly fitted interior, and exterior, impact extruded
galvanized roof jacks.
Tools & Other Building Materials Required for Kit Installation:
1. One Screw Driver
2. One Hammer
3. (4) Four galvanized barbed shank roofing nails with 3/8″to 7/16″ inch diameter flat heads.
4. Paintable Caulking for roof slopes under 3″ & 12″.
5. Spray Paint (optional)
Application of Retro-Spin Flashing Kit:
A Retro-Spin Flashing Kit installs a new roof jack flashing around roof penetrations that are fixed. These
fixed penetrations may not allow for a standard slide-on-from-the-top flashing installation. Both the
Retro-Spin Flashing and Retro-Split Collar open to allow a flashing installation from the side.
Apply the roofing up to the roof penetration. Notch or cut a hole in the roofing material to allow the
installation of the roofing product to the centerline of the roof penetration. Do not install the roofing
material further than the penetration. Use the roofing materials manufacturer’s recommendations for
installing the roof up to and around roof penetrations.
Arrange the Retro-Spin Flashing so the interior and exterior flashings provide an open door to the center of
the flashing.
Move the Retro-Spin Flashing to the roof penetration. Pass the penetration inside the Retro-Spin Flashing.
After the roof penetration is within the confines of the Spin-flashing, rotate the assembly 180 degrees. The
action of rotation closes the door and surround the penetration.
Center the Retro-Spin flashing on the roof penetration. With the door closed, and the assembly at 180
degrees face the door in the direction of the down slope of the roof deck. If the roof slope is greater to or
equal to 3″ and 12″, no sealant or caulking is required at the closed door. On roof slopes below 3″ and 12″,
inject a small amount of paintable caulking between the inside and outside flashings. On dead flat
applications, solder shut the open door to create a watertight condition.
Now use the manufacturer’s recommended procedures for installing a roof jack flashing into the steep
slope-roofing product, and securely nail the Retro-Spin Flashing into place using 3/8″ flat head roofing
Please review the following installation
instructions to receive the fine quality
you expect when installing an All Style
Retro-Spin Flashing Kit.

Summary of content (2 pages)