Datasheet

Page 3 of 7 QR-QE-20/2003.08.01
6
Voltage Divider
Error
分壓誤差值
39.6% ~ 60.4%
Voltage divider error is defined the ratio of
the voltage terminals 1-2 to terminals 1-3
after the drive arm rested. 5V D.C. shall be
applied to the terminals between 1and 3 and
then voltage divider error shall be measured
with the drive arm operation on the line X-X
and Y-Y. (Terminal 1-2/Terminal 1-3 ×
100%)
分壓誤差值是
搖杆自由復歸后端子 1-2 與端
1-3 電壓比例. 5V D.C 電壓加在端子
1-3 之間,
分壓誤差值
在搖杆運作於 X-X
Y-Y 方向到底復歸后測試.(端子 1-2/端子
1-3 ×100%)
7
Contact
resistance
接觸阻抗
(ENR)
10% or less of the total resistance for
over 60°(60°included) carbon film
angle(Before the life test);
15% or less of the total resistance for
40 ° thru 60° carbon film
angle(Before the life test);
20% or less of the total resistance for
under 40°(40°included) carbon film
angle(Before the life test);
碳膜角度為 60°()以上時,全阻值的
10%以下(壽命測試前);
碳膜角度為 40°~60°時,全阻值的
15%以下(壽命測試前);
碳膜角度為 40°()以下時,全阻值的
20%以下(壽命測試前).
15% or less of the total resistance for
over 60°(60°included) carbon film
angle
(After the life test) ;
20% or less of the total resistance for
40° thru 60 ° carbon film angle
(After the life test) ;
25% or less of the total resistance for
under 40°(40°included) carbon film
angle (After the life test) ;
碳膜角度為 60°()以上時,全阻值的
15%以下(壽命測試后);
碳膜角度為 40°~60°時,全阻值的
20%以下(壽命測試后);
碳膜角度為 40°()以下時,全阻值的
25%以下(壽命測試后).
By the test angle of operation angle
測試角度為全運轉角度。