Datasheet

Page 5 of 7 QR-QE-20/2003.08.01
7
Operation
angle of
lever
搖杆使用有效
角度
Refer to attached product
drawing
見成品圖
The maximum angle of the lever pushed
to the direction of X-X and Y-Y and
45°.
搖杆推向 X-X(Y-Y) 45°方向的最大角
度.
. ENDURANCE CHARACTERISTICS 耐久性能(Single test of item 單一測試項目)
序號
NO.
ITEM
PERFORMANCE
測試條件
TEST CONDITIONS
1
Free falling
自由落下試驗
No damage and lever
deformation, but deformations
of terminals and molded parts
are allowed.
無不良產生,端子變形除外.
Height: 75cm
Number of falls: 3 times
從高度為 75 釐米落下測試 3 次後
2
Dry heat
耐熱性
Variation of total resistance
should be within
+5%
30%.
To be operated mechanically.
全阻值變化要在
+5%
30%以內,
機械方面能動作。
Temperature:+80 ±2
Time: 96 hours
The controller shall be subjected to standard
atmospheric conditions for 2 hours after which
measurement shall be made.
溫度在80±2 放置96小時.2小時后正常狀
態下測試.
3
Cold
耐寒性
The total resistance change
should be within ±20%.
To be operated mechanically.
全阻值變化要在±20%以內,
機械方面能動作。
Temperature:-30 ±2℃
Time: 96 hours
Surface moisture shall be removed, and
then the controller shall be subjected
to standard atmospheric conditions
for 2 hours after which measurement
shall be made.
溫度在-30±2℃放置 96 小時,表面水份攝
取后 2 小時正常狀態下測試.
4
Damp heat
耐濕性
Insulation resistance: more
than 10M Ω with 250V
insulation resistance tester.
The total resistance change
should be within ±20%.
To be operated mechanically.
250V 絕緣測試機測試絕緣阻
10MΩ以上,
全阻值變化要在±20%以內,
機械方面能動作.
Temperature:+60 ± 2℃
Humidity: 90~95%RH
Time: 96 hours
Surface moisture shall be subjected to
standard atmospheric conditions for 2
hours after which measurement shall be
made.
溫度在60±2℃放置96小時,表面水份攝取
2 小時正常狀態下測試.