Datasheet

Page 7 of 7 QR-QE-20/2003.08.01
2
Travel
移動量
0.5
+0.5
-0.4
mm
Put the switch lever upward, apply 2 times
of the static operating force over the lever’s
axial direction of the lever, measure the
variance of the switch stroke.
將開關操作部(搖杆)置於靜止位置,並在操
作柄中央施加兩倍於作動力之靜負荷測
量柄被壓到不動時之移動距離.
3
Push
strength
按壓強度
No mechanical and electrical
malfunction.
不得有電氣及機構上之異常現象
.
Put the switch lever upward; apply 3kgf of
the static load over the vertical direction of
the lever for 60 seconds.
將開關之操作部(搖杆)置於垂直方向,並沿
操作方向加 3kgf 之靜負荷 60 .
4
Circuit
diagram
電路圖
/
5
Contact
resistance
接觸阻抗
Less than 100 mΩ
低於 100 mΩ
Apply 2 times of the operating force of the
static load on the vertical direction of the
lever, measure the resistance by using the
Contact Resistance Tester with 1KHZ,
20mV, 5~50mA of current.
將兩倍於作動力之靜負荷加於操作柄之
中央以(1KHZ,20mV, 5~50mA)微電流接觸
阻抗計測定.
6
Insulation
resistance
絕緣阻抗
More than 100 MΩ
100 MΩ以上
A voltage of DC100V is applied between
terminals.
DC100V
之電壓加於端子間測定
.
7
Withstand
voltage
耐電壓
There shall be no damage, arc or
dielectric breakdown.
無絕緣破壞之現象
A voltage of AC 250V(50~60HZ) shall be
applied for 1 min between terminals.
AC250V(50~60HZ)電壓施加於端子間1
分鐘.
8
Rated power
額定功率
12 V DC 50 mA
Within 70
小於 70
9
Number of
cycles
開關耐久次數
Contact resistance 200mΩMAX,
No mechanical malfunction.
接觸阻抗最大 200mΩ,
機械方面能動作.
100,000 Cycles min
Other / Cycles min