AIRTITAN SERIES CRAWLSPACE AND BASEMENT VENTILATION FANS USER MANUAL
WELCOME Thank you for choosing AC Infinity. We are committed to product quality and friendly customer service. If you have any questions or suggestions, please don’t hesitate to contact us. Visit www.acinfinity.com and click contact for our contact information. EMAIL WEB LOCATION support@acinfinity.com www.acinfinity.
MANUAL CODE AT2010X2 4 PRODUCT MODEL UPC-A AIRTITAN T3 AIRTITAN T7 AIRTITAN T8 AIRTITAN T8-N AC-ATT3 AC-ATT7 AC-ATT8 AC-ATT8-N 00819137020467 00819137020474 00819137020481 00819137020498
MANUAL INDEX Manual Index ................................................................................. Page 5 Key Features ................................................................................. Page 6 Product Contents ........................................................................... Page 7 Mounting ........................................................................................ Page 8 Powering .................................................................................
KEY FEATURES 6 HEAVY DUTY BUILD QUIET PWM MOTOR INGRESS PROTECTION The fan system features a galvanized steel or aluminum mounting frame with fan guards. Fans are enclosed in steel or plastic. PWM-controlled motor features precise speed control, reduced rotor noise, and runs on energy efficient DC voltage. Fans are sealed to be dust proof and high water resistance. Can receive water splashes and high pressure water jets.
PRODUCT CONTENTS AIRTITAN T8 AIRTITAN T8-N FAN SYSTEM (x1) AIRTITAN T3 FAN SYSTEM (x1) AIRTITAN T7 FAN SYSTEM (x1) AC-ATT8 AC-ATT8-N THERMAL PROBE (x1) POWER ADAPTER (x1) WALL ANCHORS (x4) MACHINE SCREWS (x4) AC-ATT3 THERMAL PROBE (x1) POWER ADAPTER (x1) UNIVERSAL CONTROLLER (x1) MACHINE SCREWS (x4) AC-ATT7 THERMAL PROBE (x1) POWER ADAPTER (x1) UNIVERSAL CONTROLLER (x1) MACHINE SCREWS (x4) 7
MOUNTING STEP 1 Remove any existing grilles, vents, or covers on ventilation opening where you wish to install the fan unit. STEP 2 Position the fan unit over the ventilation opening. Depending on the model, the unit may be facing towards or away from the wall. Please be sure to check the airflow direction prior to installation.
MOUNTING STEP 3 (Foundation Block Mounting) To install the unit onto a foundation brick or block, mark the mounting hole locations using the four corners of the metal face plate. Then drill 5/16" holes with a drill bit. Install wall anchors into openings and secure the unit into the wall with four screws. Note that the models T3 and T7 are designed for cabinet and wall mounting, and do not include wall anchors and larger type screws. AIRTITAN T8, T8N Illustration shown above.
POWERING AIRTITAN T8 T8-N STEP 1 To set up temperature monitoring, plug the male connector of the thermal probe into the designated probe port located at the bottom side of the fan unit. STEP 2 To power the unit plug in the power, plug the male connector of the corded power adapter into the designated power port located at the bottom side of the fan unit. Then plug the adapter head into an outlet.
POWERING AIRTITAN T3 T7 STEP 1 Plug the fan's male molex connector into one of the two designated probe ports located at the bottom side of the controller. STEP 2 To power the unit plug in the power, plug the male connector of the corded power adapter into the designated power port located at the bottom side of the controller. Then plug the adapter head into an outlet.
PROGRAMMING 1. MODE BUTTON This button cycles through each of the controller's modes: ON, OFF, TIMER, AUTO (4 triggers), and ALARM (4 settings). (AIRTITAN T8, T8N Screen Display) 1 (AIRTITAN T3, T7 Screen Display) 8 5 8 5 7 6 7 6 3. LEAF BUTTON This turns the display off while programs run in the background. Hold for two seconds to lock or unlock the display. 2. UP / DOWN BUTTON The up and down buttons adjusts the settings of the mode that you are in.
PROGRAMMING MODE SETTING Press the Mode button to cycle through the controller’s available programming modes and settings: ON Mode, OFF Mode, TIMER Mode, AUTO Mode (4 triggers), ALARM Settings (4 settings). ON MODE In this mode, the fans will run continuously regardless of temperature or humidity. The speed set in this mode will be the max speed the fans can reach in AUTO Mode. OFF MODE In this mode, the fans will not run regardless of temperature or humidity.
PROGRAMMING AUTO MODE: HIGH TEMP. In this mode, press the up or down button to set a high temperature trigger. The fans will activate if the probe’s measured temperature exceeds the temperature you have set in this mode. The activated fans will slowly increase in speed until it reaches the speed set in ON Mode. Whenever the measured temperature falls below your set temperature, the fans will slowly decrease in speed until the fans stop.
PROGRAMMING AUTO MODE: HIGH HUMID. In this mode, press the up or down button to set a high humidity trigger. The fans will activate if the probe’s measured humidity exceeds the humidity you have set in this mode. The activated fans will slowly increase in speed until it reaches the speed set in ON Mode. Whenever the measured humidity falls below your set humidity, the fans will slowly decrease in speed until the fans stop.
PROGRAMMING ALARM SETTING: HIGH TEMP. In this settings mode, press the up and down button to set a high temperature alarm. The alarm will activate if the probe’s measured temperature exceeds the temperature you have set in this mode. When the alarm triggers, the fan will start spinning gradually to max speed regardless of your other settings. You may also hold the up and down button simultaneously to turn off this alarm, in which the digits under settings will show OFF.
PROGRAMMING ALARM SETTING: HIGH HUMID. In this settings mode, press the up and down button to set a high humidity alarm. The alarm will activate if the probe’s measured humidity exceeds the humidity you have set in this mode. When the alarm triggers, the fan will start spinning gradually to max speed regardless of your other settings. You may also hold the up and down button simultaneously to turn off this alarm, in which the digits under settings will show OFF.
PROGRAMMING FAHRENHEIT OR CELSIUS To change to displayed units between Fahrenheit and Celsius, please set the controller to OFF Mode, then hold the up button for Fahrenheit (°F) or hold the down button for Celsius (°C). DISPLAY BRIGHTNESS To adjust the brightness of the display, please set the controller to OFF Mode, then press the up or down button to increase or decrease the brightness level. Four brightness settings are available.
PROGRAMMING ALERT ICONS On the top left of the display is the alert icon section. Icons may flash when the controller wishes to alert you that a particular function or alarm is being triggered. DISPLAY LOCK ALERT This icon is visible when the controller has been locked. The icon will flash to alert you that the controller is locked if you try to change the mode or settings. HUMIDITY ALARM ALERT This icon will flash when the high or low humidity alarm that you have set has been triggered.
AIRTITAN FAQ Q: Can I mount this crawlspace fan vertically? A: Yes. The AIRTITAN can be mounted in any orientation, including vertically. Q: Can I splice the cables to extend them or use my own probe? A: We do not recommend hardwiring or splicing our fan's power wires. Such modifications may compromise electrical safety and will void this product's warranty. Q: How do I reverse the airflow of my crawlspace fan? A: To flip the fan blades, unscrew the bolts from the steel plate and the body.
AIRTITAN FAQ Q: Does this fan include grilles for outside installation or duct tubes for wall installation? A: This product does not come included with ducting or grilles as accessories. Q: Is this fan waterproof? A: The AIRTITAN is IP44 rated for resistance against splashing water. Q: Will this fan help with Radon mitigation? A: Yes. The AIRTITAN will ventilate your crawlspace to exhaust radon gas emitting from soil.
AC INFINITY PRODUCTS Register Booster Fans The AIRTAP series is a line of register booster fans designed to quietly increase airflow coming from your central heat and air conditioning systems, increasing comfort for your home. Features a thermal controller with intelligent programming that will automatically adjust airflow strength in response to heating and cooling temperatures you have set.
WARRANTY This warranty program is our commitment to you, the product sold by AC Infinity will be free from defects in manufacturing for a period of two years from the date of purchase. If a product is found to have a defect in material or workmanship, we will take the appropriate actions defined in this warranty to resolve any issues. The warranty program applies to any order, purchase, receipt, or use of any products sold by AC Infinity or our authorized dealerships.