Installation and Owner’s Manual ! Read these instructions. ! Failure to follow maintenance guidelines may result in a cancellation of warranty Reach Ins Stainless Steel BSR**-HC BSF**-HC BSR**T-HC BSF**T-HC **/23,49,72/ **/23T,49T,72T/ BLUR **-HC BLUF ** -HC BLPT** -HC BLMT** -HC **/28,36,48,60,72/ and optional Drawer models Work top models Food Prep Tables Undercounters Blue Air FSE, LLC www.blueairfse.com 223 W, Rosecrans Ave. Gardena, CA 90248 . T. (310) 808-0102 • (866) 677-8500 • F.
Installation and Operation Guide Contents 1. 2. 3. 4. 5. Warnings & Safety Precautions --------------- 1 Installation -------------------------------------------- 3 Operation Guide ------------------------------------ 6 Maintenance, Cleaning --------------------------- 7 Troubleshooting ------------------------------------ 9 1. Warnings & Safety Precautions Refrigeration units that contain Hydrocarbon (R-290) See Below: • Danger - Risk of fire or explosion. Flammable refrigerant used.
Installation and Operation Guide • Unplug the appliance before cleaning and making repairs. • Use caution, the unit does remain powered when system controls are used to turn off unit. • Unplug unit before replacing the interior light • Do not plug several appliances into the same wall outlet. • After unplugging the appliance, wait at least five minutes before re-plugging it into a wall outlet. • Any deterioration in the insulation may cause fire.
Installation and Operation Guide 2. Installation 1) Remove the wooden pallet : Before you start to install your Blue Air unit, carefully inspect it for freight damage. If damage is discovered, immediately file a claim with the delivery freight carrier. Blue Air is not responsible for damage incurred during shipment. Unscrew the bolts shown in Figure 1 (Reach-in 4M13 Bolts and Undercounter 2-M6 Bolts) To ensure that your unit works properly from the first day, it must be installed properly.
Installation and Operation Guide 3) Assembling casters: 4) Leveling: (1). Reach-ins (Figure3): Install casters in the bottom rails assembly on the bottom of the unit. It is important in order to achieve maximum strength and stability of the unit that you ensure that each caster is securely tightened with a 3/4" (19mm) open-ended wrench. Casters with brakes Must be installed in front. and the casters must be in contact firmly with the bottom rails of the unit.
Installation and Operation Guide 5) Ventilation: Set unit in its final location. Be sure there is adequate ventilation in your room. you may need to install an exhaust fan under the extreme heat conditions, (100°F+, 38°C+), Warning: Warranty is void if ventilation is insufficient. 6) Space clearance: Ensure air circulation around unit 7) Assemble shelf clips : • Install all the shelf clips before installing the shelves. 1) Put the tap back side of clip into the hole of the pilaster.
Installation and Operation Guide 3) How to set the temperature 8) Electrical requirements “There are several factors that will affect the proper operation of your refrigerator. Among these factors, the electrical installation is the most important and should always be checked before connecting your refrigerator as follows: “ 1) Make sure the electrical installation complies with national, state, and local codes. 2) Make sure the circuit is properly grounded.
Installation and Operation Guide 4. Maintenance, Clean For keeping the best efficiency, it is very important to clean the condenser coil in period. Blue Air recommend to clean the condenser coil by a month. Dirty condensers result in compressor failure, product loss, and lost sales, which are not covered by warranty. If you keep the Condenser clean you will minimize your service expense and lower your electrical costs. The Condenser requires scheduled cleaning every month or as needed.
Installation and Operation Guide 3) Reach ins (top mounted compressor unit): • Take off top grille at the bottom by removing screws (only reach-in top mounted compressor model) • Clean off accumulated dirt from condensing coil and fan blades with a soft brush. 4) Cleaning the cabinet. To reduce the risk of electric shock, unplug before cleaning or service” A. Cleaning the interior and exterior • The interior and exterior of the unit can be cleaned using warm water with soap.
Installation and Operation Guide 5.
Installation and Operation Guide Blue Air has a Nationwide Service Network to provide timely services to our customer's needs. Please call or fax us at the following numbers. Blue Air Refrigeration Nationwide Service Network Toll Free, 1-866-677-8500 TEL, (310) 808-0102 Fax, (310) 808-0242/0262 www.blueairfse.