Instructions / Assembly

9
emersonfans.com
Please contact 1-800-654-3545 for further assistance
ETL Model No.: CF766
If you feel that you do not have enough electrical
wiring knowledge or experience, have your fan
installed by a licensed electrician.
CAUTION: To reduce the risk of electrical shock,
disconnect the electrical supply circuit before
installing the fan, light kit or receiver.
1. Position the supply wires to the left side of the outlet
box (Figure 14); position the fan wires to the right
side. Partially insert the remote control receiver (flat
side up) until one end rests on the hanger ball as
shown in Figure 14.
5. How to Wire Your Ceiling Fan
To avoid possible electrical shock, be sure electricity
is turned off at the main fuse box before wiring.
NOTE: If you are not sure if the outlet box is grounded,
contact a licensed electrician for advice, as it must be
grounded for safe operation.
WARNING
!
Turning off wall switch is not sufficient. To avoid
possible electrical shock, be sure electricity is turned
off at the main fuse box before wiring. All wiring must
be in accordance with National and Local codes and
the ceiling fan must be properly grounded as a
precaution against possible electrical shock.
WARNING
!
NOTE: Make all wiring connections using wire
connectors (supplied). Make sure that all
connections are tight, including ground, and that no
bare wire is visible at the wire connectors, except
for the ground wire.
2. Refer to Figure 14 and 15 and connect the receiver
wires to the supply wires and the fan motor wires as
follows:
a. Securely connect the green grounding wires from the
hanger ball and the hanger bracket to the supply
grounding conductor (this may be a bare wire or a
wire with green insulation).
b. Securely connect the supply white (neutral) wire to
the receiver white (AC IN N) wire.
c. Securely connect the supply black wire (hot) wire to
the receiver black (AC IN L) wire.
Check to see that all connections are tight, including
ground, and that no bare wire is visible at the wire
connectors, except for the ground wire. Do not
operate fan until blades are in place. Noise and fan
damage could result.
WARNING
!
GREEN GROUND WIRE
FROM HANGER BRACKET
RECEIVER
RED WIRE
RECEIVER WHITE
WIRE
FAN WHITE WIRE
ANTENNA
A
C
I
N
AC IN L
FOR BOTTOM LIGHT
TO MOTOR N
RECEIVER
BLUE WIRE
RECEIVER BLACK
WIRE
RECEIVER WHITE WIRE
SUPPLY WHITE
WIRE (NEUTRAL)
SUPPLY BLACK
WIRE (HOT)
GROUND WIRE
GREEN GROUND WIRE
FROM HANGER BALL
FAN BLUE WIRE
1-1/4" THREADED
STUD (2)
FAN BLACK
WIRE
TO MOTOR L
Figure 14
STANDARD ON-OFF WALL
SWITCH OR OPTIONAL
WALL CONTROL
BLACK
BLACK
WHITE
RED
BLACK
HANGER BALL
GREEN WIRE (GROUND)
FROM HANGER BALL
AND HANGER BRACKET
TWO-CONDUCTOR
CABLE (WITH
GROUND)
BLACK
(HOT)
WHITE
GROUND
TO
120-
VOLT
SUPPLY
WHITE
BLUE
WHITE
WHITE
BLUE
Figure 15
d. Securely connect the fan motor white wire to the
receiver white (TO MOTOR N) wire.
e. Securely connect the fan motor black wire to the
receiver red (TO MOTOR L) wire.
f. Securely connect the fan motor blue wire to the
receiver blue (FOR LIGHT) wire.
BP7471-2 4TH AVE 2/4/14 9:43 AM Page 9