Manual

12
5. Repeat steps 3 and 4 to set a run time for each station you wish to
assign to the selected program.
6. Repeat steps 2 through 5 for each program as necessary.
MASTER VALVE/PUMP START ON/OFF
The Custom Command enables automatic operation of the Master
Valve/Pump Start output circuit to be controlled independently for
each watering program. For example, if a program is used for drip
irrigation and the system pump is not required, the Master
Valve/Pump Start output circuit can be shut off whenever that
program begins operation.
The factory setting is
ON for each program. Use the steps below to
select the operation of this feature for each program as necessary.
1. Turn the function dial to the
Station Times
position.
2. Select Program
A
,
B
,
C
or
D
with the
Program
switch.
3. Press the
NEXT
button repeatedly until MASTER VALVE is displayed.
4. Press the
OFF
or
ON
button to display the operation of the master
valve/pump start output for the selected program.
5. Repeat steps 2 through 4 for each program as necessary.
SETTING PROGRAM START TIME(S)
This procedure is used to set the watering cycle start time(s) for each
program. A maximum of 16 start times can be allocated to the four
programs in any manner. Each start time will initiate a sequential
watering cycle of all stations with an assigned run time in the program.
Note: When 16 start times have been allocated, the display will show
NONE REMAINING when attempting to assign additional start times.
To set program cycle start time(s):
1. Turn the function dial to the
Program Start Times
position.
2. Select Program
A
,
B
,
C
or
D
with the
Program
switch.
3. Use the
+ and/or buttons to display the start time.
Note: To remove a start time, adjust the time to display OFF
(located between 11:59 p.m. and 12:00 a.m.).
4. Press the
NEXT
button to assign another start time to the program.
5. Repeat steps 2 through 4 for each program as necessary.
Programming the Controller