Manual

16
MANUAL OPERATIONS
Manual operation allows you to run individual stations or start automatic
watering programs as needed. The Custom Command provides separate
dial positions for each type of operation: Single Station and Program
Cycle.
SINGLE STATION
This option enables individual stations to be operated for an untimed
duration (turned On/Off) or operated for a selectable duration from
one minute to 10 hours.
1. Turn the function dial to the
Manual Single Station
position.
2. Select Program
A
,
B
,
C
or
D
with the
Program
switch.
Note: The programmed status of the master valve/pump start in
the selected program determines whether the master valve/pump
start will be activated with the manual operation.
3. Use one of the following options to operate the station.
For untimed operation:
A. Press the
NEXT
button as necessary to display the station you
wish to operate.
B. Press the
ON
button. The station will turn on and remain on
until one of the following occurs:
The
OFF
button is pressed
The controller clock passes midnight
The function dial is moved to another position
For timed operation:
A. Press the
NEXT
button as necessary to display a station you wish
to operate.
B. Use the + and/or buttons to set the desired amount of station
run time (for this operation only), from one minute to 10 hours.
C. To select additional stations to operate in sequence, repeat steps
A and B as desired. Each station will operate one-by-one in the
order they were selected.
D. Leave the function dial in the Manual
Single Station
position until the manual operation is complete,
then return the dial to the
Run
position.
Operating the Controller