Error Solution
All valves 1. Verify program: station time, watering start
will not times, watering days schedule, current time,
turn on current day, water budget and rain delay.
automatically
2. Check valve common wire for proper
connection.
3. Check for a shorted station; refer to
How the electronic circuit breaker works
on page 5.
5. Ensure rain sensor (if installed) is properly
connected and functioning properly.
If rain
sensor is not installed, ensure the
SENSOR SWITCH is in BYPASS position.
6. Check fuse, replace if necessary. See p. 27.
Cannot 1. Disconnect power to controller for
program 1 minute. Reconnect power and reprogram.
2. Install fresh 9-volt alkaline battery.
3. Verify that all 16 start times are not in
use by other programs.
Controller 1. Verify watering start times, current time
skips a cycle and watering days schedule.
No display 1. Check power source for tripped circuit
breaker.
2. If control module has been removed, this
is a normal battery-saving feature. Turn dial
to any position to reactivate display.
3. Disconnect power to controller for
1 minute. Reconnect power and reprogram.
4. Replace battery
5. Check fuse, replace if necessary. See p. 27.
Appendix A
TROUBLESHOOTING
Troubleshooting