Manual
26
❖ Error Solution
❖ Valve 1. Check station times and water budget.
stays on
2. C
heck for Manual mode; place dial in
the
Run position.
3. Disconnect valve wire. If still on, valve
malfunction is indicated.
4. Check for manual bleed closure at valve.
❖ Valve will 1. Ensure dial is not in Off / Rain Delay
not turn on
position or Rain Delay mode active.
2. Verify program: station time, watering start
times, watering days schedule, current time,
current day and water budget.
3. Make sure common wire and valve wire are
correctly connected.
4. Check for a shorted station, refer to page 5.
5. If using sensor, check sensor.
6. Check for blown fuse. Replace if necessary.
See page 27 for fuse replacement information.
❖ “Short” or 1. See “How the Electronic Circuit Breaker
“Master Valve” Works” on page 5 for troubleshooting
is displayed information.
❖ Waters too 1. Too many program start times set. Check
often each program to determine the number of
start times assigned and remove as necessary.
Troubleshooting