Use and Care Manual

4
Welcome!
This mist fan with its unique appearance and exquisite workman-
ship is easy to operate. Functions include an oscillating fan, ultra-
sonic humidifier, mosquito repellent, ice gel pack insert, anion, aro-
matherapy, and temperature display. These seven functions can be
used in unison or independently of one another. The mist fan can
help you to stay cool during the hot season and keeps your air com-
fortably humid during the dry season to create a natural and relax-
ing environment.
CAUTION
To reduce the risk of electric shock, keep plug away from water
Do not touch ultrasonic atomizer while operating, may result in injury
Keep small objects away from fan guard and mist cover to prevent damage
The water level switch will automatically turn off to protect the MIST function if
the water level is too low
Water put into the tank should be less than 40° Fahrenheit
Do not put metals and chemicals into the tank, this is dangerous and will harm
the mist function
Before replacing mosquito incense, turn the mosquito function to off for at least 5
minutes
Keep flammable items away from the mosquito repellent
Infants, elderly, or those who are weak should not sit directly in the airflow for
extended periods of time
Damaged power cords should be replaced by the manufacturer, maintenance de-
partment, or other qualified professional to avoid harm
9
Problem Possible Causes
Solution
Unit is on
but not
working
1. The motor does not work
2. The voltage is too low
3. The spindle of the motor is locked
4. The circuit board is broken
5. The capacitor is not working
1. Start high speed
2. Increase the rated voltage
3. Attempt to pull the motor cover
from its jammed position
4. Have the circuit board replaced
5. Inspect the welding of the capaci-
tor or install a new capacitor
Fan out of
balance
1. Rear fan guard is loose
2. Blade screw is loose
3. Blade is unstable or broken
4. Blade is unbalanced
1. Tighten the fan guard
2. Tighten the blade screw
3. Replace the blade
4. Turn the blade 180° then install
Atomizer is
running but
there is no
mist
1. The water in the tank is alkaline
2. The water tank is broken or
cracked
1. Clean water tank, spray barrel and
sink several times
2. Empty the water from the sink and
replace the tank
Atomizer is
not working
1. The float is not up 1. Manually pull float up
Indicator
light is on,
fan and mist
are not
working
1. Fan is unplugged
2. Power switch is off
1. Connect the plug
2. Turn the mist switch on
Indicator
light is on,
mist is not
working
1. No water in the tank
2. Mist switch is off
3. The float is loose
1. Fill the water tank with distilled
water
2. Turn on the switch
3. Tighten the float
Foul odor
from mist
1. New product, first use
2. Internal tank needs cleaned
1. Open tank cap and store the tank in
a cool, dry location
2. Clean the tank and replace the
water
Other
problems
1. Charred smell from motor
2. Exposed wire, damaged insulation
3. Rear motor shell is hot
4. Rear motor shell is broken and fan
guard is damaged
1. Stop using, send for maintenance
2. Stop using, send for maintenance
3. Turn fan off and let it cool down
4. Send to replace the parts
TROUBLESHOOTING