User manual

56
Programming system security
70 # After the wrong code has been entered 10 times, the
device locks out access for 30 seconds..
71 # After the wrong code has been entered 10 times, the de-
vice switches contact “DURESS“ to ground. The device
remains in this state until user code 1 is entered and the
# key is pressed. You can connect a suitable telephone
dialler, a transistor switch or similar device to this con-
tact. Be sure to stay within the loading specifications
of this output
72 5 - 10 # The number of times a wrong code can be entered can
be set to a value between 5 and 10. After the specified
number of wrong code entries, the device locks out ac-
cess for 15 minutes.
This lockout can be removed prematurely by entering
the master code.
Programming system security
76 00 # Codes can be wrongly entered any number of times. No
lockout period.
Programming the door activity alarm
80 1 # Active Alarm after forceful opening (without access
code or using the door opener) the connection between
the terminal “(-) GND“ and terminal “DOOR SENS“.
80 0 # No alarm after opening the connection between the ter-
minal “(-) GND“ and terminal “DOOR SENS“.