Installation Guide
What’s In The Box
One (1) DLE One (1) Romex ConnectorOne (1) Driver
ATTENTION:
• Turn power o before inspection, installation, or removal.
• Suitable for use in dry, damp and wet indoor and outdoor locations. Use only on 120 VAC, 60Hz circuits.
DLE LED Recessed Downlight
INSTALLATION INSTRUCTIONS
Model(s):
DLE4-10-120-XX-RD-WH
Model(s): DLE4-10-120-XX-SQ-WH
Model(s): DLE6-10-120-XX-RD-WH
Model(s): DLE6-10-120-XX-SQ-WH
Tools Needed
This LED Recessed Downlight requires very few
tools for installation. A screwdriver a wrench and a
pair of wirecutters will help to install the driver and
downlight .
Identify xture location and cut rough-in hole per
the following chart:
1
Installing the DLE LED Recessed Downlight
Make sure all power is turned o before beginning installation
WARNING:
• Risk of electric shock. Disconnect power at fuse or circuit breaker before installing or servicing.
• To prevent early lamp failure, lamp should only be installed in operating environments between -20°C and + 40°C (104°F and -4°F)
• No user serviceable parts inside. To avoid electric shock do not disassemble product.
• This product is not intended for use in emergency light xtures or exit signs.
• This product is contains a chemical know to the state of California to cause cancer, birth defects and other reproductive harm.
• Risk of re or electrical shock. Install this kit only in luminaires that have the construction features and dimensions shown in
the photographs and/or drawings.
• To prevent wiring damage or abrasion, do not expose wiring to edges of sheet metal or other sharp objects.
DLE4-RD: 4.25” - 4.75” Round
DLE4-SQ: 4.25” x 4.25” Square
DLE6-RD: 6.00” - 7.25” Round
DLE6-SQ: 6.5” x 6.5” Square
Attach Romex Connector to junction box.
2