Installation Guide
NICOR, Inc. | 2200 Midtown Place NE, Albuquerque, NM 87107 | 800.821.6283 | www.nicorlighting.com | rev 12.10.14
DLS Surface Mount LED Downlight
INSTALLATION INSTRUCTIONS
Model(s): DLS4-20XX-120-#K-&&
4” Housing Installation
Make sure power is turned o to the recessed housing and remove any
existing trim, lamp and mounting bracket (if any) and remove the socket
from the plate.
Install the friction clips on the back of the xture.
Screw the Edison base into the socket and carefully route the wires into the
xture.
Align the friction clips to the housing and press the xture ush to the
ceiling.
1
2
3
4
3
4
Standard 4” J-Box Installation
Secure xture ground wire to the bracket with the green ground screw and
splice to the building ground wire.
Mount the bracket to the existing J-Box with 2 mounting screws (included)
Cut o the Edison screw base and strip both wire ends. Make sure building
live (black) and neutral (white) wires are accessible from the J-Box and splice
the xture wires to the building wires with wire nuts (included): black to live
(black) and white to neutral (white).
Carefully tuck the wires into the J-Box, align the spring clips on the xture
to the bracket holes and push the xture ush to the ceiling, snapping the
clips into the bracket.
1
1
2
2
3
4
4
WARNING:
•Risk of electric shock. Disconnect power at fuse or circuit breaker before installing or servicing.
•To prevent early lamp failure, lamp should only be installed in operating environments between -20°C et + 40°C (104°F et -4°F)
•No user serviceable parts inside. To avoid electric shock do not disassemble product.
•This product is not intended for use in emergency light xtures or exit signs.
ATTENTION:
Turn power o before inspection, installation, or removal.
Suitable for use in wet locations. Use only on 120VAC, 60Hz circuits.
NOTE: This luminaire has been modied and can no longer operate the originally intended lamp. The
provided label must be applied to the retrotted luminaire where visible during re-lamping.
Title 24 Installation:
For installation in a Title24 compliant housing with a GU10 or GU24 base: Cut o
the Edison socket from the xture and strip the wires. Splice both leads to the GU