Weather Sensor Menu
CURRENT ADJUST ---
TEMPERATURE   81
°
F
RAIN STATUS   DRY
       29
°
F
DRYOUT DAYS   02
SENSORS
→
FREEZE OFF AT
Current Adjust
e percentage that the weather sensor is going to adjust the 
irrigation runtime. Possible values range between OFF and 
+150; in the majority of cases, the values will display between 
±35%. For example, if the evapotranspiration (ET) historical 
data calls for a hot season, but the week has in fact been 
cloudy, the “Current Adjust” might show "-20%" to reect the 
decreased runtime. It can also display OFF. 
Temperature
Displays the current temperature at the sensor location. 
Temperature unit (Celcius or Farenheit) can be changed in the 
controller preferences settings (see the EVOLUTION® user 
manual).
Rain Status
Displays the state of the rain sensor: DRY or WET.
Freeze O
e temperature at which irrigation will be turned o due to 
cold temperatures. Selections range from 29°- 45°F in 2 degree 
increments. is feature can also be toggled to "OFF".
1.  Press   or   to raise or lower the temperature value, 
or turn feature o.
2.  Press   to input the value.
  It is possible to disable the Freeze O feature. 
Lowering the temperature past 29°F will show OFF. 
Press   the to input the value. 
Dryout Days
After a rain, it is not always necessary to resume irrigation right 
away. Setting a Dryout Days period, from zero to 14 days, 
delays the automatic resumption of irrigation.
1.  Press   or   to increase or decrease the number of 
days to “dryout”.
2.  Press   to input the value. 
Water Adjust
Water Adjust allows the runtime of all stations in all schedules 
to which the Weather Sensor has been assigned to be adjusted 
by a maximum of ±35%. For example, if the programmed 
runtime for station 1 is 10 minutes, setting a Water Adjust of 
+35% would adjust that run time to 13 minutes, 30 seconds. 
is is useful for seasonal changes.