10
Water Now
Water Now is used to manually activate a schedule, zone(s), or to test all zones.
 Note: At any point, you can return to the previous menu by pressing the Left   button or return to the main screen by 
pressing the   HOME button.
Manually Activate a Schedule
Step  1  –  Press the   WATER NOW button.
Step  2  –  Use the Up   or Down   arrows to navigate to SCHEDULE. Press SELECT  . Watering will begin.
e selected schedule will run and activate all assigned zones.
(For controllers with multiple active schedules only.) 
Use the Up   or Down   arrows to select the Schedule you want to activate. Press SELECT  .
WATER NOW
SCHEDULE A 
SCHEDULE B
ZONES 
 Note: e Schedule name can be customized using the EVOLUTION
®
 Software which can be accessed at 
www.toro.com/evolution.
Step  3  –  From the Home Screen, the schedule can be advance by pressing the Right   arrow.
HOME 
06:02AM 
MON
  09/08
SCHEDULE A
ZONE 1 
00:02
ALERT: PRESS HELP
is Example shows Zone 1 of Schedule A is active with 2 minutes of runtime remaining.
Manually Activate a Specific Zone(s)
Step  1  –  Press the   WATER NOW button.
Step  2  –  Use the Up   or Down   arrows to navigate to ZONES. Press SELECT  .
 Note: e Zone name can be customized using the EVOLUTION
®
 Software which can be accessed at 
www.toro.com/evolution.
Step  3  –  Use the Up   or Down   arrows to select the specic zone to activate. Press the Right   arrow or SELECT  .
WATER NOW
ZONE 1  OFF
ZONE 2  -–:10
ZONE 3  OFF
Step  4  –  Use the Up   or Down   arrows to assign the zone a runtime. Press SELECT  .
e zone will activate until the specied runtime expires. A water drop icon is displayed to indicate that the zone is actively 
watering.
Step  5  –  Repeat Steps 3 and 4 to activate additional zones. Watering will occur in the order that the zones are entered.
Manually Activate All Zone Test
Step  1  –  Press the   WATER NOW button.
Step  2  –  Use the Up   or Down   arrows to navigate to ALL ZONE TEST. Press the Right   arrow or SELECT  .
WATER NOW
SCHEDULE 
ZONES 
ALL ZONE TEST  02:00
Step  3  –  Use the Up   or Down   arrows to assign a runtime. Press SELECT  .
 Note: e EVOLUTION
®
 controller will sequentially water all active zones (zones with runtimes) starting with Zone 1. 
All active zones will run the specied runtime duration. 
 Note: All Zone Test will not aect the AUX schedule. AUX Schedule is normally used for lighting.