Specification

SECTION 07 42 34
FOUNDATION INSULATION PROTECTION
PART 1 GENERAL
1.01 WORK INCLUDED
A. Foundation insulation protection.
1.02 RELATED SECTIONS
A. Division 03 - Concrete.
B. Section 07 21 13 - Board Insulation.
1.03 ENVIRONMENTAL REQUIREMENTS
A. During installation and for not less than 48 hours before and after,
ambient temperature and relative humidity shall be within limits required by
type of adhesive used.
PART 2 PRODUCTS
2.01 PRODUCTS
A. Protection Board:
1. Material: Fiberglass reinforced plastic.
2. Thickness: 0.060 inch nominal.
3. Color: Neutral light/medium gray.
4. Panel Height: Cover insulation without horizontal seams.
5. Acceptable Manufacturers:
a.
Ground Breaker by Nudo Products, (800) 826-4132.
B. Trim:
1. Material: Extruded vinyl.
2. Color: Match panel color.
3. Pieces: Cap, outside corner, inside corner, and divider.
4. Manufacturer: by panel manufacturer.
C. Accessories:
1. Adhesive: As recommended by manufacturer.
2. Rivets: Nylon drive rivets, color to match panel color.

Summary of content (2 pages)