ECO Switch
When you flip the ECO switch to the energy-saving position, the generator enters an energy-saving
state. This means that when the generator is disconnected or using lower amounts of power, the engine
will automatically return to a lower-speed state, thus reducing the amount of fuel consumed by the engine.
Full-Speed Function
When the ECO switch is not in the energy-saving position, the engine will continue to run at full speed
all the time.
DC and USB Output Function
The DC output voltage at no load is 12-18 V, and should only be used with 12 V DC terminals, such
as batteries. The USB output voltage is 5 V and can be used to charge digital products.
Parallel Function
If you want to make use of the power output from two generators for use with high-power equipment,
you will need a parallel connect box to run the two generators in parallel. The combined output
power will be 3.4 kW when the two generators are connected in this manner.
Charging Cable