Use and Care Manual

16
2) If the power cord is ne, check the wires behind the rocker
switch to see if they are burned.
3) If the wires are well, too, the PCB board might be broken and
need to be replaced. Please contact service team for a
replacement and instrucon.
3. The heater does not work, it turns on for several seconds then shuts
off itself.
1) New product:
a. Turn the thermostat to 8 to see if the heater will work
connuously.
b. If not, unplug the unit for a whole night.
c. If sll not, contact service team for a checking instrucon,
the fan assembly should be checked.
2) Product has been used for some me:
a. Open the top panel to check if the fan can move smoothly or
the heater motor is well connected.
b. If yes, pull othe CN3 connecter plugged on the PCB board.
If the heater works, the buon panel should be replaced.
c. If the heater sll does not work aer unplugging the CN3
connecter, please contact service team for a further
soluon.
4. There is no air coming out when turn the heater on.
1) New product:
a. Conrm if the air outlet feels warm or there is something
geng red inside when the heater is turned on. If yes, the
fan is stuck or the heat motor is not in right posion.
b. If not, check the heater connecters on PCB board. Unplug
and replug all connecters to see if the heater will work.
2) Product has been used for some me:
a. Conrm if the air outlet feels warm or there is something
geng red inside when the heater is turned on. If yes, the
fan is stuck or the heat motor is not in right posion.
b. If not, please contact service team for help.
5. The heater does not come back even the room is already cold.
Turn the thermostat to 8 to see if the heater will work connuously,
if yes, the sensor is malfuncon, if not, please contact service team