Universal Walk-In Bathtubs 5701 NW 35 Avenue Miami, FL 33142 PHONE: 877-360-4454 FAX: 866-560-1060 www.universaltubs.com
Page 8
ELECTRICAL PREPARATION
ELECTRICAL PREPARATION
All electrical wiring must be installed in accordance with the National Electrical Code and with all local codes. All wiring shall be done 
by a qualified electrician. Run one, two or three branch circuits (as required) from the main electrical service panel to the pump area 
of the framing structure to provide power to the unit.
Electrical components have specific wiring requirements. Refer to the matrix below for the electrical supply requirements for the jet 
massage bathtub and factory installed components.
Branch circuits must be rated for 110 – 120 volts. Use 12 Gauge, 3 conductor cable for the circuits. If the length run exceeds 100 
feet check with local codes for requirements. Install moisture proof junction box(s) 6” above the floor at the pump end of the framing 
for each circuit.
NOTE: DO NOT INSTALL THE JUNCTION BOX(S) WHERE IT CAN BE REACHED WHILE SITTING OR STANDING IN THE TUB OR 
TOUCHING THE FAUCETS.
AUTO DRAIN™, LIGHTS, WHIRLPOOL, AIR SPA, COMBO & HEATER ELECTRIAL 
REQUIREMENTS
This section lists the factory installed components of the Jet Massage and/or Air Massage Systems.
Systems 
Electrical Rang 
Circuit 1 
Dedicated 
Circuit 
Soaker w / Auto Drain™ 
15 Amp GFCI 
Soaker w / Light 
15 Amp GFCI 
Soaker w / Auto Drain™ w / Light 
15 Amp GFCI 
Jet Massage Or Air Massage 
15 Amp GFCI 
Jet Massage Or Air Massage w / Light 
15 Amp GFCI 
Jet Massage Or Air Massage w/ Auto Drain™ 
15 Amp GFCI 
Jet Massage Or Air Massage w/ Light & Auto Drain™ 
15 Amp GFCI 
Jet Massage & Air Massage (Dual) 
20 Amp GFCI 
Jet Massage & Air Massage (Dual) w/ Light 
20 Amp GFCI 
Jet Massage & Air Massage (Dual) w/ Auto Drain™ 
20 Amp GFCI 
Jet Massage & Air Massage (Dual) w/ Light & Auto Drain™ 
20 Amp GFCI 
Whirlpool Inline Heater - Dedicated 15 Amp Circuit 
15 Amp GFCI 
All electrical connections must be carried out b y a certified electrician in accordance with local electrical requirements and codes.