Installation Guide

Limited Warranty
(Valid only in U.S.A., Canada, Puerto Rico, and the Caribbean.)
Lutron will, at its option, repair or replace any unit that is defective in materials or manufacture within one year after purchase. For warranty service, return unit
to place of purchase or mail to Lutron at 7200 Suter Rd., Coopersburg, PA 18036-1299, postage pre-paid.
THIS WARRANTY IS IN LIEU OF ALL OTHER EXPRESS WARRANTIES, AND THE IMPLIED WARRANTY OF MERCHANTABILITY IS LIMITED TO ONE YEAR FROM
PURCHASE. THIS WARRANTY DOES NOT COVER THE COST OF INSTALLATION, REMOVAL OR REINSTALLATION, OR DAMAGE RESULTING FROM MISUSE,
ABUSE, OR DAMAGE FROM IMPROPER WIRING OR INSTALLATION. THIS WARRANTY DOES NOT COVER INCIDENTAL OR CONSEQUENTIAL DAMAGES.
LUTRON’S LIABILITY ON ANY CLAIM FOR DAMAGES ARISING OUT OF OR IN CON NEC TION WITH THE MANUFACTURE, SALE, INSTALLATION, DELIVERY, OR
USE OF THE UNIT SHALL NEVER EXCEED THE PUR CHASE PRICE OF THE UNIT.
This warranty gives you specific legal rights, and you may have other rights which vary from state to state. Some states do not allow the exclusion or limitation of
incidental or consequential damages, or limitation on how long an implied warranty may last, so the above limitations may not apply to you.
Lutron, Claro, and Maestro are registered trademarks and FASS is a trademark of Lutron Electronics Co., Inc. NEC is a registered trademark of the National Fire
Protection Association, Quincy, Massachusetts.
© 2011 Lutron Electronics Co., Inc.
030-1526 030-1526
English
Canopy Module
CM-L300FQ1: 120 V~ 60 Hz (300 W light / 1 A fan)
Wall Control
MA-LFQ35: 120 V~ 60 Hz 3.5 A (one CM-L300FQ1)
Important Notes
Please read before installing.
1. CAUTION: To avoid overheating and possible damage to other equipment, do not use to control receptacles,
fluorescent or neon lighting fixtures, transformer-supplied appliances, solid state fan motors, or exhaust fans.
For exhaust fans, use Lutron
® fully variable fan speed controls.
2. Install in accordance with all national and local electrical codes.
3. When no “grounding means” exist in wallbox, the 2011 National Electrical Code
® (NEC®) allows a control to be
installed as a replacement if 1) a nonmetallic, noncombustible faceplate is used with nonmetallic attachment screws
or 2) the circuit is protected by a ground fault circuit interrupter (GFCI). When installing a control according to these
methods, cap or remove green wire before screwing control into wallbox.
4. The Maestro
® dual fan/light control system consists of a Wall Control and a Canopy Module. Both must be installed
correctly before attempting to control the fan/light fixture. Do not attempt to mix Lutron
® controls with those from
other manufacturers, or mix Lutron
® controls not labeled for use together.
5. This system is not compatible with fans having a control system built into the motor.
6. Do not paint Wall Control or Canopy Module.
7. Do not use where total lamp wattage is less than 40 W or greater than 300 W.
8. Operate between 32 °F and 104 °F (0 °C and 40 °C) room temperature. For indoor use only.
9. Wall Control may feel warm to the touch during normal operation.
10. Recommended wallbox depth is 2.5 inches (64 mm) minimum.
11. Clean Wall Control with a soft damp cloth only. Do not use any chemical cleaners.
12. This system cannot be used to change the direction of the fan. To change the fan direction, stop the fan, and then
change the position of the switch located on the body of the fan.
13. To maximize light bulb life, use bulbs recommended for fan or “rough service” use.
14. Do not use pull chains to operate fan/light after installing this system.
15. Canopy Module must be installed within a fan canopy enclosure.
16. This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this
device may not cause harmful interference, and (2) this device must accept any interference received, including
interference that may cause undesired operation.
Quiet Fan Speed Control and Halogen/Incandescent Dimmer
Single-Location System (MA-LFQHW)
Fan/Light
Warning: For use with one ceiling paddle fan and light only. Do not use with
an exhaust fan or more than one fan.
One ceiling fan only No exhaust fans
Multigang Installations
When installing more than one control in the same wallbox, it may be necessary to remove all inner side sections prior to
wiring (see below). Using pliers, bend side sections up and down until they break off. Repeat for each side section to be
removed. Note: Product does not require derating when side sections are removed.
Breaking Side
Sections
Technical Assistance
If you have questions concerning the installation or operation of this product, call the
Lutron Technical Support Center. Please provide exact model number when calling.
U.S.A. and Canada (24 hrs/7days): +1.800.523.9466
México +1.888.235.2910
Other countries 8am – 8pm ET: +1.610.282.3800
Fax +1.610.282.1243
http://www.lutron.com
Lutron Electronics Co., Inc.
7200 Suter Road
Coopersburg, PA 18036-1299, U.S.A.
P/N 030-1526 Rev. A 12/2011
Inside sections
are removed from
each control
Side sections are
removed from both
sides of middle control
Do not remove
outside sections.
NOTE: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to
Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a
residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and
used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no
guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to
radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try
to correct the interference by one or more of the following measures:
– Reorient or relocate the receiving antenna.
– Increase the separation between the equipment and receiver.
– Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
– Consult the dealer or an experienced radio/TV technician for help.
Troubleshooting
Operation
Light Level Tap Button
•Tap once when lights are off
Lights brighten smoothly to preset intensity.
•Tap once when lights are on Lights dim smoothly to off.
•Tap twice quickly – Lights brighten rapidly to full intensity.
•Pressandholdwhenlightsareon– Activates delayed
fade to off mode. As the tap button is held, the LEDs will
begin to flash. The first flashing LED represents a 10
second fade to OFF. Each additional flashing LED represents
an additional 10 seconds of delay before lights fade to OFF
(up to 60 seconds of delay).
Fan Speed Tap Button
•Tap once when fan is off
Fan speed increases to preset level.
•Tap once when fan is on Fan speed slows to off.
•Tap twice quickly – Fan speed increases to full speed.
Light Level LEDs
Indicate approximate light level
LEDs may not change with
each press
Press to increase light level
Press to decrease light level
Fan speed LEDs
Indicate exact fan speed
LEDs will change with each press
Press to increase fan speed
Press to decrease fan speed
FASSTM
Front Accessible
Service Switch
IMPORTANT NOTICE:
To replace bulb, remove power by pulling
the FASS
switch out on the Wall Control.
For any procedure other than routine bulb
replacement, power must be disconnected
at the main electrical panel.
Reference Wiring Diagram
Canopy
Module
Junction box and Canopy
Live
120 V~
60 Hz
Neutral
White
Black
Wall Control
Wallbox
Ceiling Fan and Light
Red (Light)
Yellow (Fan)
Green
Brass
Brass
Ground
Switched Live
®
Symptom Probable Cause and Action
Light or fan does not turn ON
or no LEDs turn ON.
•FrontAccessibleServiceSwitch(FASS
) on Wall Control is pulled out
to the OFF position.
•Manualswitchonfanisoff(ex:pullchain).
•Lightbulb(s)burnedout.
•BreakerisOFFortripped(orfuseblown).
•Fandirectionswitchisbetweenforwardandreverse.
•Wiringerror,callLutron Technical Support Center.
Upper LEDs on Wall Control cycle rapidly and
bottom LED is ON.
•Unit is not activated properly. Activate system as described in Step 14.
•Wiringerror,callLutron Technical Support Center.
Upper LEDs on Wall Control cycle rapidly and
second lowest LED is ON.
•Communicationerror.Checkwiring;iferrorcontinues,call
Lutron Technical Support Center.
Fan vibrates or wobbles. •Fanbladesnotproperlybalanced.Seefanmanufacturer’s
instructions.
Light dims in large steps and fan is noisy or does
not spin at correct speed.
•FanandlightcontrolwiresonCanopyModulearereversed.
Light button controls fan and vice-versa. •FanandlightcontrolwiresonCanopyModulearereversed.
Fan speed is too slow. •Fanpullchainnotsettohigh.
Wall Control LEDs respond as expected but fan
and/or light does not respond properly.
•Fanand/orlightpullchainsnotsettohigh/on.
•Wiringerror,callLutron Technical Support Center.

Summary of content (2 pages)