SETTINGS AND ADJUSTMENTS
Buttons function and Operation Description
# Name Function & Operation
1 POWER
Standby mode: Press the POWER button to turn the unit on. Press
again to turn unit off. Unit will operate at default settings for
1,600 sq. ft.
2 LCD Screen
Displays the unit’s working status; FAN, PUFIFY, OZONE and
TIMER.
3 FAN
Press to adjust the fan speed. (Note: the coverage area changes
200 sq. ft. each time the FAN button is pressed).
4 PURIFY
Press to adjust the ozone output - 0 to 5 settings - (Note: the cov-
erage area changes 200 sq. ft. each time you press the PURIFY
button).
5 UV
Press to turn the UV bulb on or off.
6 OZONE
Press to turn the ozone generator on or off (Note: The PURIFY
settings do not work when OZONE is off).
7 AWAY
Air purifier works at maximum settings, 3,000 sq. ft., in AWAY
mode. The purifier will shut off when the timer returns to 0.
Press once for a 0.5 hour run time; Press twice for a 1 hour run
time; Press third time for a 2 hour run time; Press again to return
to manual mode.
8, 9,
10
LED lamps for
Away Mode
Indicates timing mode: means 0.5H;Ⅱ means 1 hour;Ⅲ
means 2 hours.
11 Receiver
Infrared receiver (Note: do not block the receiver, otherwise it
will affect the normal working of the air purifier).
12 Timer Off
Press buttons 3 & 5 at the same time, display will show 0:00 for
timer, press button 4 (PURIFY) within 2 seconds to set timer.
The time increases by 0.5 hour each time you press the button.
When timer runs out, the unit will automatically revert to previous
working status.
(Note: press any button to turn off the timer function)
11
TROUBLESHOOTING GUIDE
Indicators of Operation:
(Operation of the Ozone & Power Indicator
Lamp)
The ozone generator should be operated
when the room is unoccupied. Open the
door and window when you return to the
room if ozone operated for several hours.
Turn the unit on and check that the small
red/orange lamp is illuminated. The lamp
is located on the front panel; one is
silkscreen ‘POWER and the other is
silkscreen ‘OZONE’.
Troubleshooting What to look for first:
Unit does not operate:
Is the unit plugged in?
Is the power cord fully inserted into the back of the unit?
Are you sure the outlet is functioning normally?
Is the unit turned on?
(The power switch, located on the back of the unit, marked l/O is flipped up)
Is the back grill installed properly to depress the safety switch forward?
Air flow is restricted or reduced:
Is the unit properly placed away from objects that may obstruct air
flow?
Are the filters clean?
I have plugged in the unit, turned the power switch, located on the back of the
unit, to "ON" and pressed the POWER button and nothing is happening. What's
wrong?
Make sure the electrical outlet is capable of providing power to the unit.
Check that the back cover is fully installed and snapped into place. If the
back cover is not fully installed, a safety switch will not allow the unit to
turn on.
Check to see if the proper fuse is installed and that it is serviceable.
Ensure that the fuse cap is completely seated and secured in its receptacle.
See Page 10 for more details.
Be sure the cord is fully plugged into the unit and also into the wall outlet.
Customer Service (877) 467-8643